Literature DB >> 7369297

Basal precorneal tear turnover in the human eye.

M J Puffer, R W Neault, R F Brubaker.   

Abstract

We studied 51 normal subjects with a simple method that permits measurement of the rate of fluorescein loss from the central precorneal tear film. In 15 (29%), no measurable dye remained 30 minutes after application of 1 microliter of a 10% solution of sodium fluorescein into the lower culde-sac. In 31 (61%) of the subjects, an exponential decay of the dye was observed between 15 and 30 minutes after application. In 5 (10%) of the subjects, a prolonged increase in dye concentration was observed, followed by a steady decrease that began 30 to 45 minutes after application. One eye of one subject had a steady increase in dye concentration for over an hour, and this eye was excluded from the analysis. The mean value for the tear elimination coefficient in all subjects analyzed was 15%/min. The logarithm of the tear elimination coefficient appeared to be normally distributed within the population sample. Analysis of the frequency distribution permitted an estimate that the 95% confidence limits for the tear elimination coefficient, as measured by this method, was 5 to 30%/min. No statistically significant correlations were found between tear elimination coefficient and sex, eye color, or contact lens use.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7369297     DOI: 10.1016/0002-9394(80)90006-9

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  12 in total

Review 1.  Aging and the lacrimal system.

Authors:  N J Van Haeringen
Journal:  Br J Ophthalmol       Date:  1997-10       Impact factor: 4.638

Review 2.  Tear exchange and contact lenses: a review.

Authors:  Alex Muntz; Lakshman N Subbaraman; Luigina Sorbara; Lyndon Jones
Journal:  J Optom       Date:  2015-01-07

3.  Continuous fluorophotometric method of measuring tear turnover rate in humans and analysis of factors affecting accuracy.

Authors:  W R Webber; D P Jones
Journal:  Med Biol Eng Comput       Date:  1986-07       Impact factor: 2.602

4.  A new technique for tear film fluorophotometry.

Authors:  N Eter; M Göbbels
Journal:  Br J Ophthalmol       Date:  2002-06       Impact factor: 4.638

5.  Correlation of tear clearance rate and fluorophotometric assessment of tear turnover.

Authors:  K P Xu; K Tsubota
Journal:  Br J Ophthalmol       Date:  1995-11       Impact factor: 4.638

6.  Simultaneous evaluation of tear turnover and corneal epithelial permeability by fluorophotometry in normal subjects and patients with keratoconjunctivitis sicca (KCS).

Authors:  J D Nelson
Journal:  Trans Am Ophthalmol Soc       Date:  1995

7.  Frequent association of delayed tear clearance in ocular irritation.

Authors:  P Prabhasawat; S C Tseng
Journal:  Br J Ophthalmol       Date:  1998-06       Impact factor: 4.638

8.  Effect of eledoisin on tear volume and tear flow in humans as assessed by fluorophotometry.

Authors:  M Göbbels; J Selbach; M Spitznas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

9.  Determination of basal tear turnover in insulin-dependent diabetes mellitus patients by fluorophotometry.

Authors:  T R Stolwijk; J A van Best; H H Lemkes; R J de Keizer; J A Oosterhuis
Journal:  Int Ophthalmol       Date:  1991-11       Impact factor: 2.031

10.  Measurement of basal tear turnover using a standardized protocol. European concerted action on ocular fluorometry.

Authors:  J A van Best; J M Benitez del Castillo; L M Coulangeon
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-01       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.