Literature DB >> 7366129

[Computer-analysis of volume distribution curves of erythrocytes (author's transl)].

A Schäfer, W Schäfer.   

Abstract

The erythrocyte diameter curve of Price-Jones exhibits symmetrical, normal distribution. In contrast, the volume distribution curve of erythrocytes shows an asymmetrical course with some skewness to the right, which with different haematological diseases may vary. With respect to differential diagnosis as well as to therapy it is of importance to have available an objective means of comparing curves with different shapes. We therefore developed a mathematical determination of the volume distribution curves, which derived from the overlapping of two Gaussian normal distribution curves. Volume distribution curves of erythrocytes were determined with an electronic particle counter (Coulter counter) in 271 healthy and haematologically affected children as well as in 3 adults. With only one exception all volume distribution curves of erythrocytes could be fitted using computer analysis and the constants m1, m2, s1 and s2 were calculated. Characterisation of the curves with only these 4 constants allows a simple qualitative as well as quantitative comparison of different volume distribution curves.

Entities:  

Mesh:

Year:  1980        PMID: 7366129     DOI: 10.1007/bf01477272

Source DB:  PubMed          Journal:  Klin Wochenschr        ISSN: 0023-2173


  23 in total

1.  [Erythrocyte diameter in child].

Authors:  H WEICKER; I WAGNER; A B GUTTMANN; F KRIEGER; H F LOHREY; H VON ZIMMERMANN
Journal:  Acta Haematol       Date:  1953-07       Impact factor: 2.195

2.  Comparison of techniques improving the resolution of standard Coulter cell sizing systems.

Authors:  W Von Behrens; S Edmondson
Journal:  J Histochem Cytochem       Date:  1976-01       Impact factor: 2.479

3.  A volume-activated cell sorter.

Authors:  E Menke; E Kordwig; P Stuhlmüller; V Kachel; G Ruhenstroth-Bauer
Journal:  J Histochem Cytochem       Date:  1977-07       Impact factor: 2.479

4.  Fluvo-metricell, a combined cell volume and cell fluorescence analyzer.

Authors:  V Kachel; E Glossner; E Kordwig; G Ruhenstroth-Bauer
Journal:  J Histochem Cytochem       Date:  1977-07       Impact factor: 2.479

5.  [An electronic method for the improvement of volume analysis in Coulter's particle sizing volumetric technic].

Authors:  V Kachel
Journal:  Blut       Date:  1973-10

6.  [Electronic determination of the volume of blood corpuscles and it's sources of errors].

Authors:  R Thom; A Hampe; G Sauerbrey
Journal:  Z Gesamte Exp Med       Date:  1969-12-31

7.  [The volume distribution curve of erythrocytes in hematologic diagnosis].

Authors:  H Becker; J P Kaltwasser
Journal:  Dtsch Med Wochenschr       Date:  1968-08-09       Impact factor: 0.628

8.  [Influence of the particle penetration trajectory on the volume distribution curve, according to the Coulter principle].

Authors:  V Kachel; H Metzger; G Ruhenstroth-Bauer
Journal:  Z Gesamte Exp Med       Date:  1970

9.  The skewness of volume distribution curves of erythrocytes.

Authors:  H Winter; R P Sheard
Journal:  Aust J Exp Biol Med Sci       Date:  1965-12

10.  Automatic erythrocyte volume analysis. Price-Jones curve determination.

Authors:  A Kelly; R E Davis
Journal:  Lab Pract       Date:  1967-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.