Literature DB >> 7360783

Some sources of artefact in computed tomography.

P S Tofts, J C Gore.   

Abstract

A number of sources of error and artefact that may arise in X-ray computed tomography are considered. The importance of temporal and spatial non-uniformities in X-ray tube output and detector sensitivity, of changes in voltage supply, of an incomplete field of view, and of scattered radiation, are analysed by calculating their effect on the reconstructed image, and by estimating the noise power that they introduce. Computer simulation is used whenever the error is dependent on the object. The particular relevance of these errors in CT scanners employing arrays of detectors, such as an image intensifier, is emphasised.

Mesh:

Year:  1980        PMID: 7360783     DOI: 10.1088/0031-9155/25/1/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET.

Authors:  Mohammad Reza Ay; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-19       Impact factor: 9.236

Review 2.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

Review 3.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

4.  Correlation of cone beam computed tomography (CBCT) findings in the maxillary sinus with dental diagnoses: a retrospective cross-sectional study.

Authors:  Dan Dominik Brüllmann; Irene Schmidtmann; Silke Hornstein; Ralf K Schulze
Journal:  Clin Oral Investig       Date:  2011-10-04       Impact factor: 3.573

5.  Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes.

Authors:  Homa Hayati; Asghar Mesbahi; Mahmood Nazarpoor
Journal:  Radiol Phys Technol       Date:  2015-07-25

6.  A new method for experimental characterisation of scattered radiation in 64-slice CT scanner.

Authors:  A Akbarzadeh; Mr Ay; H Ghadiri; S Sarkar; H Zaidi
Journal:  Biomed Imaging Interv J       Date:  2010-01-01

7.  Improving image accuracy of region-of-interest in cone-beam CT using prior image.

Authors:  Jiseoc Lee; Jin Sung Kim; Seungryong Cho
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

8.  Feasibility study of shutter scan acquisition for region of interest (ROI) digital tomosynthesis.

Authors:  Dohyeon Kim; Byungdu Jo; Donghoon Lee; Haenghwa Lee; Sunghoon Choi; Hyemi Kim; Zhen Chao; Seungyeon Choi; Hee-Joung Kim
Journal:  J Appl Clin Med Phys       Date:  2018-03-01       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.