Literature DB >> 7351928

An outbreak of Legionnaires' disease associated with a contaminated air-conditioning cooling tower.

T J Dondero, R C Rendtorff, G F Mallison, R M Weeks, J S Levy, E W Wong, W Schaffner.   

Abstract

In August and September 1978, an outbreak of Legionnaires' disease occurred in Memphis, Tennessee. Of the 44 ill, 39 had been either patients, employees, visitors, or passers-by at one Memphis hospital (Hospital A) during the 10 days before. Assuming an incubation period of between two and 10 days, the onset of cases correlated precisely with the use of Hospital A's auxiliary air-conditioning cooling tower. L. pneumophila was recovered from two samples of water from the tower. Infection appeared to have occurred both outside and within the hospital. A significant association was demonstrated between acquisition of Legionnaires' disease and prior hospitalization in those areas of Hospital A that received ventilating air from air intakes near the auxiliary cooling tower. Tracer-smoke studies indicated that contaminated aerosols from the tower could easily reach these air intakes, as well as the street below, where four passers-by had been before they contracted Legionnaires' disease. This represents a common-source outbreak in which the source of L. pneumophila infection and airborne transmission were identified.

Entities:  

Mesh:

Year:  1980        PMID: 7351928     DOI: 10.1056/NEJM198002143020703

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  106 in total

1.  Sporadic cases of community acquired legionnaires' disease: an ecological study to identify new sources of contamination.

Authors:  D Che; B Decludt; C Campese; J C Desenclos
Journal:  J Epidemiol Community Health       Date:  2003-06       Impact factor: 3.710

2.  Molecular characterization of Legionella populations present within slow sand filters used for fungal plant pathogen suppression in horticultural crops.

Authors:  Leo A Calvo-Bado; J Alun W Morgan; Martin Sergeant; Tim R Pettitt; John M Whipps
Journal:  Appl Environ Microbiol       Date:  2003-01       Impact factor: 4.792

3.  Legionellosis: Why should I test and report?

Authors:  Thomas J Marrie; Jason R Garay; Erica Weir
Journal:  CMAJ       Date:  2010-07-05       Impact factor: 8.262

4.  Coinoculation with Hartmannella vermiformis enhances replicative Legionella pneumophila lung infection in a murine model of Legionnaires' disease.

Authors:  J Brieland; M McClain; L Heath; C Chrisp; G Huffnagle; M LeGendre; M Hurley; J Fantone; C Engleberg
Journal:  Infect Immun       Date:  1996-07       Impact factor: 3.441

5.  A large Legionnaires' disease outbreak in Pamplona, Spain: early detection, rapid control and no case fatality.

Authors:  J Castilla; A Barricarte; J Aldaz; M García Cenoz; T Ferrer; C Pelaz; S Pineda; B Baladrón; I Martín; B Goñi; P Aratajo; J Chamorro; F Lameiro; L Torroba; I Dorronsoro; V Martínez-Artola; M J Esparza; M A Gastaminza; P Fraile; P Aldaz
Journal:  Epidemiol Infect       Date:  2007-07-30       Impact factor: 2.451

6.  Enhanced chlorine resistance of tap water-adapted Legionella pneumophila as compared with agar medium-passaged strains.

Authors:  J M Kuchta; S J States; J E McGlaughlin; J H Overmeyer; R M Wadowsky; A M McNamara; R S Wolford; R B Yee
Journal:  Appl Environ Microbiol       Date:  1985-07       Impact factor: 4.792

7.  Proliferation of Legionella pneumophila as an intracellular parasite of the ciliated protozoan Tetrahymena pyriformis.

Authors:  B S Fields; E B Shotts; J C Feeley; G W Gorman; W T Martin
Journal:  Appl Environ Microbiol       Date:  1984-03       Impact factor: 4.792

8.  Legionnaires' disease caused by Legionella dumoffii in distilled water.

Authors:  J R Joly; P Déry; L Gauvreau; L Coté; C Trépanier
Journal:  CMAJ       Date:  1986-12-01       Impact factor: 8.262

9.  Distribution of sequence-based types of legionella pneumophila serogroup 1 strains isolated from cooling towers, hot springs, and potable water systems in China.

Authors:  Tian Qin; Haijian Zhou; Hongyu Ren; Hong Guan; Machao Li; Bingqing Zhu; Zhujun Shao
Journal:  Appl Environ Microbiol       Date:  2014-01-24       Impact factor: 4.792

10.  Effects of three oxidizing biocides on Legionella pneumophila serogroup 1.

Authors:  E L Domingue; R L Tyndall; W R Mayberry; O C Pancorbo
Journal:  Appl Environ Microbiol       Date:  1988-03       Impact factor: 4.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.