Infant endotracheal tube resistance: effects of changing length, diameter, and gas density.

M A Wall.   

Abstract

Endotracheal tube resistance may increase upper airway resistance and the work of breathing beyond the normal range in adults of children who are chronically intubated and receiving intermittent mandatory ventilation. The purpose of this study was to measure the resistance of infant endotracheal tubes (IETTs) over the range of normal infant respiratory flows while systematically changing length, diameter, and carrier gas density. Resistance was measured in IETTs of 2.5, 3.0, and 3.5 mm inner diameter at flows increasing from 10--150 ml/sec, using both air and 80% helium- 20% oxygen (He-O2) as the carrier gases. Tube length was progressively shortened from full length to 4.8 cm in 2-cm increments, and resistance to both air and He-O2 was measured at all lengths. Reynolds' number calculations and the relationship of resistance to flow showed the flow regime in IETTs to be transitional in nature. Increasing tube diameter, decreasing length, or decreasing gas density led to large decreases in IETT flow resistance. Over the range of normal infant flows, IETT resistance is equal to or higher than that of the normal upper aiaway. IETT resistance might increase the work of breathing in some infants to the point of respiratory failure, and such resistance may be lowered by systematic changes in IETT diameter, length, or carrier gas density.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7349947

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  7 in total

1.  In vitro comparison of nasal continuous positive airway pressure devices for neonates.

Authors:  A G De Paoli; C J Morley; P G Davis; R Lau; E Hingeley
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2002-07       Impact factor: 5.747

2.  Ventilator Y-piece pressure compared with intratracheal airway pressure in healthy intubated children.

Authors:  Omer Nasiroglu; Bruce Craig Weldon; Lawrence S Berman; Ikram Ul Haque
Journal:  J Clin Monit Comput       Date:  2006-05-16       Impact factor: 2.502

3.  Comparison of two different CPAP systems by tidal breathing parameters.

Authors:  Thomas Hückstädt; Bertram Foitzik; Roland R Wauer; Gerd Schmalisch
Journal:  Intensive Care Med       Date:  2003-05-27       Impact factor: 17.440

4.  [Preserved spontaneous breathing during partial liquid ventilation. Results of experimental animal studies and their clinical implications].

Authors:  H D Hummler; F Pohlandt; A Schulze
Journal:  Anaesthesist       Date:  2003-12       Impact factor: 1.041

5.  Asymptomatic congenital subglottic stenosis in a neonate - infant feeding tube as a "Guardian angel!"

Authors:  Chetna Shamshery; Ashish Kumar Kannaujia; Rajashree Madabushi; Vansh Priya
Journal:  Saudi J Anaesth       Date:  2018 Apr-Jun

6.  Incidence and Outcomes of Acute Laryngeal Injury After Prolonged Mechanical Ventilation.

Authors:  Justin R Shinn; Kyle S Kimura; Benjamin R Campbell; Anne Sun Lowery; Christopher T Wootten; C Gaelyn Garrett; David O Francis; Alexander T Hillel; Liping Du; Jonathan D Casey; E Wesley Ely; Alexander Gelbard
Journal:  Crit Care Med       Date:  2019-12       Impact factor: 7.598

7.  Comparison of Respiratory Support After Delivery in Infants Born Before 28 Weeks' Gestational Age: The CORSAD Randomized Clinical Trial.

Authors:  Snorri Donaldsson; Thomas Drevhammar; Yinghua Li; Marco Bartocci; Siren Irene Rettedal; Fredrik Lundberg; Per Odelberg-Johnson; Tomasz Szczapa; Thordur Thordarson; Ingrida Pilypiene; Thordur Thorkelsson; Lars Soderstrom; Vladimiras Chijenas; Baldvin Jonsson
Journal:  JAMA Pediatr       Date:  2021-09-01       Impact factor: 26.796

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.