Literature DB >> 7337055

Clinicopathologic correlations in pseudocapsule formation after breast augmentation.

H Jenny, J Smahel.   

Abstract

In 2,000 patients who underwent augmentation mammoplasties with different types of prostheses, the thickness of the pseudocapsules around gel-filled implants was greater than that of the pseudocapsules forming around inflatable implants. This observation was corroborated by an independent histologic study. Deposition of liquid silicone into the pseudo-capsules as well as the adjacent breast tissue and migration into capillaries was demonstrated. Until an impermeable shell or a non-transgressive gel can be manufactured, gel-filled implants should not be used.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7337055     DOI: 10.1007/bf01981684

Source DB:  PubMed          Journal:  Aesthetic Plast Surg        ISSN: 0364-216X            Impact factor:   2.326


  9 in total

1.  Histology of the capsules causing constrictive fibrosis around breast implants.

Authors:  J Smahel
Journal:  Br J Plast Surg       Date:  1977-10

2.  "Bleeding" of silicone from bag-gel breast implants, and its clinical relation to fibrous capsule reaction.

Authors:  D E Barker; M I Retsky; S Schultz
Journal:  Plast Reconstr Surg       Date:  1978-06       Impact factor: 4.730

3.  Foreign material in the capsules around breast prostheses and the cellular reaction to it.

Authors:  J Smahel
Journal:  Br J Plast Surg       Date:  1979-01

4.  Foreign body reaction to silicone rubber. Complication of a finger joint implant.

Authors:  R G Aptekar; J M Davie; H S Cattell
Journal:  Clin Orthop Relat Res       Date:  1974 Jan-Feb       Impact factor: 4.176

5.  Histological investigation of the etiology of capsule contracture following augmentation mammaplasty.

Authors:  E Domanskis; J Q Owsley
Journal:  Plast Reconstr Surg       Date:  1976-12       Impact factor: 4.730

6.  Myofibroblasts and free silicon around breast implants.

Authors:  R Rudolph; J Abraham; T Vecchione; S Guber; M Woodward
Journal:  Plast Reconstr Surg       Date:  1978-08       Impact factor: 4.730

7.  Exudation of silicone through the envelope of gel-filled breast prostheses: an in vitro study.

Authors:  R B Bergman; A E van der Ende
Journal:  Br J Plast Surg       Date:  1979-01

8.  Silicone lymphadenopathy and synovitis. Complications of silicone elastomer finger joint prostheses.

Authors:  A J Christie; K A Weinberger; M Dietrich
Journal:  JAMA       Date:  1977-04-04       Impact factor: 56.272

9.  Silicon identification in prosthesis-associated fibrous capsules.

Authors:  M G Wickham; R Rudolph; J L Abraham
Journal:  Science       Date:  1978-01-27       Impact factor: 47.728

  9 in total
  1 in total

1.  Capsular contraction and deflation associated with inflatable implants.

Authors:  J E Price
Journal:  Aesthetic Plast Surg       Date:  1983       Impact factor: 2.326

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.