Literature DB >> 7335308

Automated variable contrast acuity testing.

M A Mainster, G T Timberlake, C L Schepens.   

Abstract

The results of clinical trials with a simple system for automating visual acuity measurements are presented. An inexpensive microcomputer: (1) presents acuity targets on a television screen, (2) uses patients' responses entered through a remote response box to control a staircase testing procedure, and (3) prepares a printed record of a patient's mean visual acuity and its standard deviation. The automated method: (1) offers a stable measure of visual performance, (2) provides an immediate analysis of the statistical significance of changes measured in visual acuity from one office visit to the next, and (3) gives results that are in general agreement with conventional chart testing methods when high contrast targets are used on the television screen. In addition, when medium and low contrast targets are used, the automated method provides a variable contrast acuity profile (VCAP), which describes visual performance at contrast levels that are vital to a patient's performance in daily life but not examined in conventional chart testing. VCAPs are measured clinically, and it is shown that the extent that a patient's acuity declines with decreasing contrast cannot be predicted from the patient's high contrast acuity. Automated variable contrast acuity testing is found to provide a simple, reproducible, clinically practicable method of documenting and quantitating the extent of a patient's visual difficulties at medium and low contrasts.

Entities:  

Mesh:

Year:  1981        PMID: 7335308     DOI: 10.1016/s0161-6420(81)80035-8

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  4 in total

Review 1.  Why HID headlights bother older drivers.

Authors:  M A Mainster; G T Timberlake
Journal:  Br J Ophthalmol       Date:  2003-01       Impact factor: 4.638

2.  Measurement of contrast sensitivity function using pattern-reversal visual evoked responses.

Authors:  O Katsumi; T Tanino; T Hirose
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1985       Impact factor: 3.117

3.  Contrast Sensitivity with Center-distance Multifocal Soft Contact Lenses.

Authors:  Augustine N Nti; Hannah R Gregory; Eric R Ritchey; James S Wolffsohn; David A Berntsen
Journal:  Optom Vis Sci       Date:  2022-04-01       Impact factor: 2.106

4.  High- and Low-contrast Letter Acuity during Image Motion in Normal Observers and Observers with Infantile Nystagmus Syndrome.

Authors:  Harold E Bedell; Sop Song
Journal:  Optom Vis Sci       Date:  2021-02-01       Impact factor: 2.106

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.