Interrelationship between lung volume, expiratory flow, and lung transfer factor in fibrosing alveolitis.

J N Pande.   

Abstract

Fifty patients with fibrosing alveolitis studied on 104 occasions exhibited significant direct correlations between vital capacity (VC), maximum mid-expiratory flow rate (MMFR), and transfer factor for carbon monoxide (TLCO). Forced expired volume in the first second (FEV1)/VC ratio bore a weak negative correlation with VC. Peak expiratory flow, MMFR, and maximum flow rates at 50% and 25% of VC were often reduced in patients with severe grades of pulmonary dysfunction. It appears that as the severity of the fibrotic process increases, the lung volumes shrink and the transfer factor for CO decreases. The total lung capacity decreases predominantly on account of reduction in VC. With a decrease in lung volume the MMFR also falls. Decrease in flow rates at low lung volumes is greater as compared to the fall in peak flow. The expiratory flow rates however were normal or even increased when related to absolute lung volume. Some patients exhibit disproportionate expiratory slowing as evidenced by a decrease in MMFR which is out of proportion to the reduction in VC. These patients also have a reduced FEV1/VC ratio. These changes are probably the consequence of associated peripheral airway narrowing.

Entities:  

Mesh:

Year:  1981        PMID: 7330809      PMCID: PMC471829          DOI: 10.1136/thx.36.11.858

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  14 in total

1.  Respiratory function tests; normal values at median altitudes and the prediction of normal results.

Authors:  H I GOLDMAN; M R BECKLAKE
Journal:  Am Rev Tuberc       Date:  1959-04

2.  The pulmonary diffusing capacity in normal subjects.

Authors:  D V BATES; N G BOUCOT; A E DORMER
Journal:  J Physiol       Date:  1955-08-29       Impact factor: 5.182

3.  Small airways in fibrosing alveolitis.

Authors:  N C Schofield; R J Davies; I R Cameron; M Green
Journal:  Am Rev Respir Dis       Date:  1976-06

4.  Normal standards for ventilatory function using an automated wedge spirometer.

Authors:  R M Cherniack; M B Raber
Journal:  Am Rev Respir Dis       Date:  1972-07

5.  Normal standards of pulmonary function tests for healthy Indian men 15-40 years old: comparison of different regression equations (prediction formulae).

Authors:  S K Jain; T J Ramiah
Journal:  Indian J Med Res       Date:  1969-08       Impact factor: 2.375

6.  Bird breeder's hypersensitivity pneumonitis: progress studies of lung function after cessation of exposure to the provoking antigen.

Authors:  D H Allen; G V Williams; A J Woolcock
Journal:  Am Rev Respir Dis       Date:  1976-09

7.  Airway function in sarcoidosis.

Authors:  R S Levinson; L F Metzger; N N Stanley; S G Kelsen; M D Altose; N S Cherniack; J S Brody
Journal:  Am J Med       Date:  1977-01       Impact factor: 4.965

8.  Mechanical properties of the lung in extrinsic allergic alveolitis.

Authors:  C P Warren; K S Tse; R M Cherniack
Journal:  Thorax       Date:  1978-06       Impact factor: 9.139

9.  The influence of lung volume on expiratory flow rates in diffuse interstitial lung disease.

Authors:  D S Jayamanne; H Epstein; R M Goldring
Journal:  Am J Med Sci       Date:  1978 May-Jun       Impact factor: 2.378

10.  A new method for measuring airway resistance in man using a body plethysmograph: values in normal subjects and in patients with respiratory disease.

Authors:  A B DUBOIS; S Y BOTELHO; J H COMROE
Journal:  J Clin Invest       Date:  1956-03       Impact factor: 14.808

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.