Literature DB >> 7322503

Blinking and the mechanics of the lacrimal drainage system.

M G Doane.   

Abstract

High-speed photography, using picture rates up to 500/sec, has confirmed many key aspects of the tear drainage process reported over the years by various investigators. The punctal openings are seen to elevate themselves from the lid margin at the start of the closing phase of the blink, allowing their forceful meeting and occlusion by the time the closing lid is halfway down. Completion of lid closure then compresses the canaliculi and lacrimal sac, forcing contained fluid through the drainage system. The elastic expansion of the channels during the opening phase of the blink forms a suction, holding the lid margins at the punctal region together as the lids open. During the latter part of this opening, the punctal areas are seen to "pop' apart suddenly as the vacuum is broken, and tear fluid from the marginal tear strips is drawn into the puncta in the first few seconds following the blink.

Mesh:

Year:  1981        PMID: 7322503     DOI: 10.1016/s0161-6420(81)34940-9

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  34 in total

1.  Ultrasonic visualization of the effect of blinking on the lacrimal pump mechanism.

Authors:  Mitrofanis Pavlidis; Tobias Stupp; Ulrike Grenzebach; Holger Busse; Solon Thanos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-09-29       Impact factor: 3.117

Review 2.  [Tear outflow. Impact of mucins and TFF-peptides].

Authors:  F Paulsen; A Corfield; M Hinz; W Hoffmann; U Schaudig; A Thale; M Berry
Journal:  Ophthalmologe       Date:  2004-01       Impact factor: 1.059

3.  Meibography: A review of techniques and technologies.

Authors:  Ryan J Wise; Rachel K Sobel; Richard C Allen
Journal:  Saudi J Ophthalmol       Date:  2012-10

4.  Botulinum toxin A treatment in patients suffering from blepharospasm and dry eye.

Authors:  J Horwath-Winter; J Bergloeff; I Floegel; E-M Haller-Schober; O Schmut
Journal:  Br J Ophthalmol       Date:  2003-01       Impact factor: 4.638

Review 5.  The watery eye.

Authors:  Jianhua Wang; Meixiao Shen; Lele Cui; Michael R Wang
Journal:  Curr Allergy Asthma Rep       Date:  2011-06       Impact factor: 4.806

Review 6.  Dynamics and function of the tear film in relation to the blink cycle.

Authors:  R J Braun; P E King-Smith; C G Begley; Longfei Li; N R Gewecke
Journal:  Prog Retin Eye Res       Date:  2014-12-03       Impact factor: 21.198

7.  A MODEL FOR THE TEAR FILM AND OCULAR SURFACE TEMPERATURE FOR PARTIAL BLINKS.

Authors:  Quan Deng; R J Braun; T A Driscoll; P E King-Smith
Journal:  Interfacial Phenom Heat Transf       Date:  2013

8.  Tear flow dynamics in the human nasolacrimal ducts--a pilot study using dynamic magnetic resonance imaging.

Authors:  Shantha Amrith; Poh Sun Goh; Shih-Chang Wang
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-12-17       Impact factor: 3.117

Review 9.  [Blinking activity during visual display terminal work. Part 1: Ocular discomfort and pathophysiological principles].

Authors:  F Ziemssen; N Freudenthaler; K Regnery; T Schlote
Journal:  Ophthalmologe       Date:  2005-08       Impact factor: 1.059

10.  Frequent association of delayed tear clearance in ocular irritation.

Authors:  P Prabhasawat; S C Tseng
Journal:  Br J Ophthalmol       Date:  1998-06       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.