Literature DB >> 7317214

Segmental quantitative analysis of digital thallium-201 myocardial scintigrams in diagnosis of coronary artery disease. Comparison with rest and exercise electrocardiography and coronary arteriography.

R J Wainwrwight, M N Maisey, E Sowton.   

Abstract

One hundred and forty-nine patients with suspected ischaemic heart disease were evaluated by exercise thallium-201 myocardial scintigraphy (201Tl SMS), single lead exercise electrocardiography, and coronary arteriography. Myocardial distribution of tracer was assessed semi-quantitatively from digital 201Tl scintigrams and compared with tracer distribution in subjects with normal hearts. Fifty-two of 54 (96%) patients with normal coronary arteries had normal myocardial scintigrams whereas three patients had a positive ischaemic exercise electrocardiogram and were scan normal. Conversely, 36 of 95 (38%) patients with coronary artery disease had a positive ischaemic electrocardiogram compared with 94 of 95 (99%) patients who had a positive myocardial scintigram. Disease in specific coronary arteries could be deduced from the topography of myocardial tracer deficit. Disease was predicted correctly in 76 out of 80 (95%) of left anterior descending coronary stenoses, in 48 out of 64 (75%) of right coronary artery stenoses, and in 55 out of 64 (85%) of left circumflex coronary artery stenosis, despite the presence of infarcted myocardium in other territories. Similarly, single vessel disease was predicted correctly in 14 out of 17 (82%) patients and multiple vessel disease in 64 out of 77 (83%) patients. 201Tl SMS with segmental quantitative analysis is a highly sensitive and specific technique in the diagnosis of coronary artery disease and may be useful screening procedure to select patients for further investigation, particularly those with evidence of life-threatening severe left coronary artery disease.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7317214      PMCID: PMC482682          DOI: 10.1136/hrt.46.5.478

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  15 in total

1.  Segmental analysis of Ti-201 stress myocardial scintigraphy.

Authors:  A Lenaers; P Block; E V Thiel; M Lebedellr; P Becquevort; F Erbsmann; A Ermans
Journal:  J Nucl Med       Date:  1977-06       Impact factor: 10.057

2.  Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease.

Authors:  G A Diamond; J S Forrester
Journal:  N Engl J Med       Date:  1979-06-14       Impact factor: 91.245

3.  Myocardial stress perfusion scintigraphy with rubidium-81 versus stress electrocardiography.

Authors:  E H Botvinick; D M Shames; K M Gershengorn; E Carlsson; R A Ratshin; W W Parmley
Journal:  Am J Cardiol       Date:  1977-03       Impact factor: 2.778

4.  Myocardial imaging with thallium-201: a multicenter study in patients with angina pectoris or acute myocardial infarction.

Authors:  J L Ritchie; B L Zaret; H W Strauss; B Pitt; D S Berman; H R Schelbert; W L Ashburn; H J Berger; G W Hamilton
Journal:  Am J Cardiol       Date:  1978-09       Impact factor: 2.778

5.  Thallium-20 1 myocardial perfusion scintigraphy for the clinical clarification of normal, abnormal and equivocal electrocardiographic stress tests.

Authors:  E H Botvinick; M R Taradash; D M Shames; W W Parmley
Journal:  Am J Cardiol       Date:  1978-01       Impact factor: 2.778

6.  Potential value of thallium-201 scintigraphy as a means of selecting patients for the coronary care unit.

Authors:  F J Wackers; K I Lie; K L Liem; E B Sokole; G Samson; J van der Schoot; D Durrer
Journal:  Br Heart J       Date:  1979-01

7.  Sensitivity and specificity of thallium-201 perfusion scintigrams under exercise in the diagnosis of coronary artery disease.

Authors:  M S Verani; M L Marcus; M A Razzak; J C Ehrhardt
Journal:  J Nucl Med       Date:  1978-07       Impact factor: 10.057

8.  Functional significance of coronary collateral circulation during dynamic exercise evaluated by thallium-201 myocardial scintigraphy.

Authors:  R J Wainwright; M N Maisey; A C Edwards; E Sowton
Journal:  Br Heart J       Date:  1980-01

9.  Correlation of exercise 201thallium myocardial scan with coronary arteriograms and the maximal exercise test.

Authors:  A P Carrillo; D S Marks; S D Pickard; F Khaja; S Goldstein
Journal:  Chest       Date:  1978-03       Impact factor: 9.410

10.  The predictive value of myocardial perfusion scintigraphy after stress in patients without previous myocardial infarction.

Authors:  D A Turner; W E Battle; H Deshmukh; M A Colandrea; G J Snyder; E W Fordham; J W Messer
Journal:  J Nucl Med       Date:  1978-03       Impact factor: 10.057

View more
  2 in total

1.  New technique for showing the relation of tomographic myocardial perfusion images obtained with thallium-201 to the coronary arteries.

Authors:  C J Gibson; E E Laird; E D Williams; A Rajathurai; B Mittra; D Rankin
Journal:  Br Heart J       Date:  1985-10

Review 2.  New imaging techniques: their relation to conventional radiology.

Authors:  R E Steiner
Journal:  Br Med J (Clin Res Ed)       Date:  1982-05-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.