Literature DB >> 7309379

Use of perfluoroalkanoic acids as volatile ion pairing reagents in preparative HPLC.

D R Harding, C A Bishop, M F Tarttelin, W S Hancock.   

Abstract

This report describes the successful use of the ether soluble, ion pairing reagents perfluoropropoinic and perfluorobutyric acid in the preparative and analytical reserved phase HPLC of underivatised peptides. The preparative separation of a 1-g sample of Pyr-His-Gly, the proposed anorexigenic peptide, is described on C18-silica which was packed in a flexible-walled cartridge and subjected to radial compression. The mobile phase consisted of an aqueous solution of perfluorobutyric acid (5 mM) and a flow rate of 100 ml/min was used. The purified peptide was simply isolated by neutralizing and freeze-drying the corresponding peak and then extracting the excess ion pairing reagent with ether. The product was then shown to be homogeneous by analytical HPLC and amino acid analysis. The tripeptide failed to show any effect on food intake, water intake or body weight in female rats. Similarly no effect was noted on the reproductive cycles of the rat.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7309379     DOI: 10.1111/j.1399-3011.1981.tb02060.x

Source DB:  PubMed          Journal:  Int J Pept Protein Res        ISSN: 0367-8377


  6 in total

1.  Context-dependent effects on the hydrophilicity/hydrophobicity of side-chains during reversed-phase high-performance liquid chromatography: Implications for prediction of peptide retention behaviour.

Authors:  C T Mant; R S Hodges
Journal:  J Chromatogr A       Date:  2006-06-30       Impact factor: 4.759

2.  Effect of anionic ion-pairing reagent concentration (1-60 mM) on reversed-phase liquid chromatography elution behaviour of peptides.

Authors:  M Shibue; C T Mant; R S Hodges
Journal:  J Chromatogr A       Date:  2005-07-01       Impact factor: 4.759

3.  The perchlorate anion is more effective than the trifluoroacetate anion as an ion-pairing reagent for reversed-phase chromatography of peptides.

Authors:  M Shibue; C T Mant; R S Hodges
Journal:  J Chromatogr A       Date:  2005-07-01       Impact factor: 4.759

4.  Effect of anionic ion-pairing reagent hydrophobicity on selectivity of peptide separations by reversed-phase liquid chromatography.

Authors:  M Shibue; C T Mant; R S Hodges
Journal:  J Chromatogr A       Date:  2005-07-01       Impact factor: 4.759

5.  Ion-interaction-capillary zone electrophoresis of cationic proteomic peptide standards.

Authors:  Traian V Popa; Colin T Mant; Robert S Hodges
Journal:  J Chromatogr A       Date:  2005-08-10       Impact factor: 4.759

6.  Ion-interaction CZE: the presence of high concentrations of ion-pairing reagents demonstrates the complex mechanisms involved in peptide separations.

Authors:  Traian V Popa; Colin T Mant; Robert S Hodges
Journal:  Electrophoresis       Date:  2007-07       Impact factor: 3.535

  6 in total