Literature DB >> 7304736

An improved liquid ion exchanger for chloride ion-selective microelectrodes.

C M Baumgarten.   

Abstract

A new chloride liquid ion exchanger, Corning 477913, suitable for fabricating ion-selective microelectrodes (ISE) is described. It differs from the standard chloride exchanger. Corning 477315, in that the concentration of organophilic ligand is increased fivefold. The properties of ISE (tip diameter less than 1 micrometer) made from the new material are superior to those of ISE made from the standard material. The yield of acceptable ISE was greater (77 vs. 34%); the ISE resistance was decreased 5.3-fold; the average slope was improved (-52.8 vs. -45.5 mV); and the selectivity over some interfering anions was increased. Measurement of intracellular chloride activity in rabbit ventricle with ISE made from the new exchanger gave results similar to those reported previously with the standard exchanger. This suggests that 477913 is satisfactory for use in biological tissue. The new formulation should be particularly advantageous for measurements requiring ISE with very fine tips and in fabrication of multibarrel ISE.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7304736     DOI: 10.1152/ajpcell.1981.241.5.C258

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  21 in total

1.  Rapid co-transport of sodium and chloride ions in giant salivary gland cells of the leech Haementeria ghilianii.

Authors:  W A Wuttke; M S Berry
Journal:  J Physiol       Date:  1990-08       Impact factor: 5.182

2.  A new double-barrelled, ionophore-based microelectrode for chloride ions.

Authors:  Y Kondo; T Bührer; K Seiler; E Frömter; W Simon
Journal:  Pflugers Arch       Date:  1989-09       Impact factor: 3.657

3.  A chloride conductance activated by adenosine 3',5'-cyclic monophosphate in the apical membrane of Necturus enterocytes.

Authors:  F Giraldez; F V Sepúlveda; D N Sheppard
Journal:  J Physiol       Date:  1988-01       Impact factor: 5.182

4.  Application of chloride-selective microelectrodes to renal test dyes and other food or cosmetic dyes.

Authors:  K H Leser; G V Sigrist
Journal:  Pflugers Arch       Date:  1986-01       Impact factor: 3.657

5.  The intracellular chloride activity of rat kidney proximal tubular cells.

Authors:  A C Cassola; M Mollenhauer; E Frömter
Journal:  Pflugers Arch       Date:  1983-12       Impact factor: 3.657

6.  Potential and K+ activity in skinned muscle fibers. Evidence against a simple Donnan equilibrium.

Authors:  R E Godt; C M Baumgarten
Journal:  Biophys J       Date:  1984-02       Impact factor: 4.033

7.  Cytotoxic effect of choline, abolished by furosemide, in the diluting segment of frog kidney.

Authors:  H Oberleithner; F Lang
Journal:  Pflugers Arch       Date:  1984-07       Impact factor: 3.657

8.  Fixed charges of the heart muscle interstitium.

Authors:  L Parent; J P Caillé
Journal:  Biophys J       Date:  1985-05       Impact factor: 4.033

9.  Intracellular chloride activities in canine tracheal epithelium. Direct evidence for sodium-coupled intracellular chloride accumulation in a chloride-secreting epithelium.

Authors:  M J Welsh
Journal:  J Clin Invest       Date:  1983-05       Impact factor: 14.808

10.  Chloride activity in cells of isolated perfused cortical thick ascending limbs of rabbit kidney.

Authors:  R Greger; H Oberleithner; E Schlatter; A C Cassola; C Weidtke
Journal:  Pflugers Arch       Date:  1983-09       Impact factor: 3.657

View more