Literature DB >> 7297344

Evaluation of the S phase distribution of flow cytometric DNA histograms by autoradiography and computer algorithms.

L E Sheck, K A Muirhead, P K Horan.   

Abstract

Cell sorting and tritiated thymidine autoradiography were used to define the distribution of S phase cells in flow cytometric DNA histograms obtained from exponential mouse lymphoma cells (L5178Y). The numbers of labeled S phase cells, autoradiographically determined from cells sorted at 2-channel intervals in the G1/early S and late S/G2M regions of the histogram, were compared with the numbers of computed S phase cells in comparable 2-channel intervals as predicted by several computer algorithms used to extract cell cycle phase distributions from DNA histograms. Polynomial and multirectangle algorithms gave computed estimates of total %S in close agreement with the tritiated thymidine labeling index for the cell population, while multi-Gaussian algorithms underestimated %S. Interval autoradiographic and algorithm studies confirmed these results in that no significant differences were found between the autoradiographic S phase distribution and S phase distributions calculated by the polynomial and multirectangle models. However, S phase cells were significantly underestimated in G1/early S by a constrained multi-Gaussian model and in both G1/early S and late S/G2 by an unconstrained multi-Gaussian model. For the particular cell line (L5178Y), staining protocol (mithramycin following ethanol fixation) and instrumentation (Coulter TPS-2 cell sorter) used in this study, close agreement between computed %S and tritiated thymidine labeling index was found to be a reliable indicator of an algorithm's success in resolving S phase cells in the G1/S and S/G2 transition regions of the DNA histograms.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 7297344     DOI: 10.1002/cyto.990010204

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  5 in total

1.  Comparison of autoradiography and DNA histograms in assessing S-phase cells from patients with myeloid leukemias.

Authors:  A Raza; A S Raza; K Kuliczkowski; S C Zhao; H D Preisler
Journal:  Med Oncol Tumor Pharmacother       Date:  1985

2.  On the inverse problem in flow cytometry recovering DNA distribution from FMF data.

Authors:  C Bruni; G Koch; C Rossi
Journal:  Cell Biophys       Date:  1983-03

3.  Cell kinetics of histologic variants of in situ breast carcinoma.

Authors:  J S Meyer
Journal:  Breast Cancer Res Treat       Date:  1986       Impact factor: 4.872

4.  Analysis of chromosome replication by a BrdU antibody technique.

Authors:  W Vogel; M Autenrieth; K Mehnert
Journal:  Chromosoma       Date:  1989-11       Impact factor: 4.316

Review 5.  Benzene-induced myelotoxicity: application of flow cytofluorometry for the evaluation of early proliferative change in bone marrow.

Authors:  R D Irons
Journal:  Environ Health Perspect       Date:  1981-06       Impact factor: 9.031

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.