Literature DB >> 7292380

Bicuspid mitral bioprosthesis.

E Bodnar, N L Bowden, P J Drury, E G Olsen, I Durmaz, D N Ross.   

Abstract

A bicuspid mitral bioprosthesis was prepared by mounting glutaraldehyde-processed porcine pericardium onto commercially available Brownlee-Yates stents. The bioprostheses were inserted into 17 dogs. Haemodynamic performance and long-term function of the valve was assessed. Of the 11 animals in the survival group, eight died within the 24-72 hour postoperative period. The clinical picture of these animals revealed progressive left ventricular failure although the bioprostheses were tested and found competent both at insertion and at necropsy. The causes of the late deaths were deterioration of the porcine pericardium in two, and cerebral embolism in another. The acute haemodynamic studies showed a significantly high closing reflux from within the tubular bioprosthesis, and this reflux was found to be inherent in the design. It was concluded that any stented bicuspid valve where the stent assumes the function of the papillary muscles, has to be tailored so that parts of the tissue can assume the function of the chordae tendineae to minimise the closing reflux.

Entities:  

Mesh:

Year:  1981        PMID: 7292380      PMCID: PMC471440          DOI: 10.1136/thx.36.1.45

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  6 in total

1.  Pericardial autografts in the mitral valve. A preliminary report.

Authors:  L R SAUVAGE; S J WOOD; A H BILL; G A LOGAN
Journal:  J Thorac Cardiovasc Surg       Date:  1962-07       Impact factor: 5.209

2.  Tissue valves in the mitral position. Five years' experience.

Authors:  D A Mary; B C Pakrashi; R W Catchpole; M I Ionescu
Journal:  Br Heart J       Date:  1975-11

3.  The in vitro assessment of left ventricular flow patterns on the closure of a new mitral valve "bioprosthesis".

Authors:  R T Brownlee; L Scotten
Journal:  Trans Am Soc Artif Intern Organs       Date:  1976

4.  A fascia lata mitral valve based on the 'frustum' principle.

Authors:  R T Brownlee; A K Yates
Journal:  Thorax       Date:  1971-05       Impact factor: 9.139

5.  The experimental and clinical use of autogenous pericardium for the replacement and extension of mitral and tricuspid value cusps and chordae.

Authors:  R W Frater; J Berghuis; A L Brown; F H Ellis
Journal:  J Cardiovasc Surg (Torino)       Date:  1965 May-Jun       Impact factor: 1.888

6.  Results of replacement of cardiac valves by homologous dura mater valves.

Authors:  E J Zerbini
Journal:  Chest       Date:  1975-06       Impact factor: 9.410

  6 in total
  1 in total

1.  Development and in vitro assessment of a new two-leaflet replacement heart valve designed using computer-generated bubble surfaces.

Authors:  D K Walker; L N Scotten; D E Hewgill; R G Racca; R T Brownlee
Journal:  Med Biol Eng Comput       Date:  1983-01       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.