Effect of lateral position and volume on the spread of epidural anaesthesia in the parturient.

S H Rolbin, A F Cole, E M Hew, S Virgint.   

Abstract

The effect of lateral positioning and the volume of drug injected on the spread of epidural anaesthesia was assessed in 131 healthy parturients. Epidural injection for anaesthesia was done at the L3-4 interspace and a catheter was inserted into the epidural space after injection of the drug. The patients were randomly assigned to four groups. The doses used were 12 ml of bupivacaine 0.25 per cent and 6 ml of bupivacaine 0.5 per cent. Patients were kept in the lateral position in which the block was done (Groups I and III) or turned to the opposite side after completion of the epidural injection (Groups II and IV). Sensory levels and maternal assessment of pain relief were determined fifteen to twenty minutes after injection. All assessments were done by a trained observer who did not know to what group the patient had been allocated. Maintenance of the lateral position after induction of epidural anaesthesia is compatible with satisfactory analgesia for labour. Twelve ml bupivacaine 0.25 per cent provides better analgesia than 6 ml bupivacaine 0.5 per cent although the same mass is injected. The quality of analgesia is improved by turning the patients to the contralateral side after injection of 12 ml bupivacaine 0.25 per cent.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7284885     DOI: 10.1007/BF03010351

Source DB:  PubMed          Journal:  Can Anaesth Soc J        ISSN: 0008-2856


  6 in total

1.  STUDIES OF THE INFERIOR VENA CAVA IN LATE PREGNANCY.

Authors:  M G KERR; D B SCOTT; E SAMUEL
Journal:  Br Med J       Date:  1964-02-29

2.  Spread of analgesic solutions in the epidural space and their site of action: a statistical study.

Authors:  P R BROMAGE
Journal:  Br J Anaesth       Date:  1962-03       Impact factor: 9.166

3.  Aortocaval compression: incidence and prevention.

Authors:  G F Marx
Journal:  Bull N Y Acad Med       Date:  1974-04

4.  Epidural anesthesia and the lateral position.

Authors:  E M Grundy; L N Rao; A P Winnie
Journal:  Anesth Analg       Date:  1978 Jan-Feb       Impact factor: 5.108

5.  Effect of maternal position on fetal heart rate during extradural analgesia.

Authors:  K Huovinen; K Teramo
Journal:  Br J Anaesth       Date:  1979-08       Impact factor: 9.166

6.  Bupivacaine, 0.125 per cent, in obstetric epidural analgesia: experience in three thousand cases.

Authors:  A Bleyaert; M Soetens; L Vaes; A L Van Steenberge; A Van der Donck
Journal:  Anesthesiology       Date:  1979-11       Impact factor: 7.892

  6 in total
  1 in total

1.  Maternal positioning affects fetal heart rate changes after epidural analgesia for labour.

Authors:  R Preston; E T Crosby; D Kotarba; H Dudas; R D Elliott
Journal:  Can J Anaesth       Date:  1993-12       Impact factor: 5.063

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.