Literature DB >> 7272123

Comparison of physical work capacity and systolic time intervals with ventricular inhibited and atrial synchronous ventricular inhibited pacing.

I Kruse, L Rydén.   

Abstract

Sixteen patients with a non-invasively programmable pacemaker (Medtronic 2409) were examined with the unit in ventricular inhibited (VVI) and atrial synchronous ventricular inhibited (VDT/I) mode, respectively. Maximal exercise capacity was determined by means of bicycle ergometry. Work load was increased in steps of 10 watts each minute. Atrial and ventricular rates, brachial artery pressure, and respiratory rate were studied at rest and during exercise while systolic time intervals were determined at rest. There was an important increase in maximal exercise capacity when changing from VVI to VDT/I pacing. The extent of improvement was the same for patients above and below the age of 65 years. At comparable work loads VDT/I pacing resulted in significantly lower atrial rates than VVI pacing. Systolic time intervals did not differ between VVI and VDT/I pacing apart from an increase in left ventricular ejection time index with VDT/I pacing. Systolic time intervals and maximal exercise capacity with VVI pacing did not correlate with the increase in exercise capacity induced by VDT/I pacing. Physical performance can be significantly improved by VDT/I pacing in both young and old patients. Exercise capacity on VVI pacing cannot predict the possible benefit of change to VDT/I pacing.

Entities:  

Mesh:

Year:  1981        PMID: 7272123      PMCID: PMC482618          DOI: 10.1136/hrt.46.2.129

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  18 in total

1.  THE IMPLANTABLE SYNCHRONOUS PACER IN THE TREATMENT OF COMPLETE HEART BLOCK.

Authors:  S CENTER; D NATHAN; C Y WU; P SAMET; W KELLER
Journal:  J Thorac Cardiovasc Surg       Date:  1963-12       Impact factor: 5.209

2.  Design of exercise test, with special reference to heart patients.

Authors:  H Aström; B Jonsson
Journal:  Br Heart J       Date:  1976-03

3.  Adaptation of the left ventricle to sudden changes in heart rate in patients with artificial pacemakers.

Authors:  I Karlöf; S Bevegård; C O Ovenfors
Journal:  Cardiovasc Res       Date:  1973-05       Impact factor: 10.787

4.  Significance of the contribution of atrial systole to cardiac function in man.

Authors:  A Benchimol
Journal:  Am J Cardiol       Date:  1969-04       Impact factor: 2.778

5.  Systolic time intervals in cardiac disease (II).

Authors:  A M Weissler; C L Garrard
Journal:  Mod Concepts Cardiovasc Dis       Date:  1971-02

6.  Systolic time intervals in cardiac disease. I.

Authors:  A M Weissler; C L Garrard
Journal:  Mod Concepts Cardiovasc Dis       Date:  1971-01

7.  Hemodynamic sequelae of atrial, ventricular, and sequential atrioventricular pacing in cardiac patients.

Authors:  P Samet; C Castillo; W H Bernstein
Journal:  Am Heart J       Date:  1966-12       Impact factor: 4.749

8.  Physiological studies and clinical experience in patients with synchronous and asynchronous pacemakers.

Authors:  S K Brockman; H A Collins; D A Bloomfield; B C Sinclair-Smith; W G Gobbel
Journal:  J Thorac Cardiovasc Surg       Date:  1966-06       Impact factor: 5.209

9.  The synchronous pacer: three years of clinical experience with 45 cases.

Authors:  S Center; D A Nathan
Journal:  Ann Surg       Date:  1966-11       Impact factor: 12.969

10.  Haemodynamic effect of atrail triggered versus fixed rate pacing at rest and during exercise in complete heart block.

Authors:  I Karlöf
Journal:  Acta Med Scand       Date:  1975-03
View more
  7 in total

1.  Indications and choices in pacemaker therapy.

Authors:  J Benrey
Journal:  Tex Heart Inst J       Date:  1991

2.  Physiological importance of different atrioventricular intervals to improved exercise performance in patients with dual chamber pacemakers.

Authors:  R J Haskell; W J French
Journal:  Br Heart J       Date:  1989-01

Review 3.  Pacemakers and exercise. Current status, future developments and practical implications of physiological pacemakers.

Authors:  N A Estes; G Brockington; A S Manolis; D Salem
Journal:  Sports Med       Date:  1989-07       Impact factor: 11.136

4.  Randomised controlled trial of physiological and ventricular pacing.

Authors:  E J Perrins; C A Morley; S L Chan; R Sutton
Journal:  Br Heart J       Date:  1983-08

5.  "Physiological" pacing.

Authors:  J S Geddes
Journal:  Br Heart J       Date:  1983-08

6.  Exercise capacity and spontaneous heart rhythm after transvenous fulguration of atrioventricular conduction.

Authors:  P M Schofield; R J Bowes; N Brooks; D H Bennett
Journal:  Br Heart J       Date:  1986-10

7.  Dual chamber pacing: how many patients remain in DDD mode over the long term?

Authors:  B Ibrahim; J E Sanderson; B Wright; R Palmer
Journal:  Br Heart J       Date:  1995-07
  7 in total