Titanium, silver, and tantalum clips in brain tissue.

H von Holst, P Collins, L Steiner.   

Abstract

The brain tissue reaction to a recently devised titanium haemoclip and to the conventional silver and tantalum clips were investigated in rabbit brain. Titanium, silver, and tantalum wires 5 X 0.5 X 0.5 mm in size were implanted into the white matter of the brain. After one and six months the brain specimens were sectioned, stained with haematoxylin eosin and with phosphotungstic acid Haematoxylin, and were studied by light microscopy. The examination revealed neither tissue reaction nor pigmentation in the case of titanium implant, while there was pigmentation surrounding the tantalum, and there was pigmentation as well as reactive gliosis around the silver wires.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7270261     DOI: 10.1007/BF01407234

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  2 in total

1.  Titanium clips in neurosurgery for elimination of artefacts in computer tomography (ct) a technical note.

Authors:  H von Holst; M Bergström; A Möller; L Steiner; T Ribbe
Journal:  Acta Neurochir (Wien)       Date:  1977       Impact factor: 2.216

2.  Tissue reaction in rabbit muscle exposed to metallic implants.

Authors:  P G Laing; A B Ferguson; E S Hodge
Journal:  J Biomed Mater Res       Date:  1967-03
  2 in total
  7 in total

1.  The Strecker stent: indications and results in iliac and femoropopliteal arteries.

Authors:  D Liermann; E P Strecker; J Peters
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Sep-Oct       Impact factor: 2.740

2.  The efficacy of silver-embedded polypropylene-grafted polyethylene glycol-coated ventricular catheters on prevention of shunt catheter infection in rats.

Authors:  Derya Burcu Hazer; Melike Mut; Nazmiye Dinçer; Zeynep Saribas; Baki Hazer; Tunçalp Ozgen
Journal:  Childs Nerv Syst       Date:  2012-02-29       Impact factor: 1.475

3.  Plasma treatment effects on the tantalum Strecker stent implanted in femoral arteries of sheep.

Authors:  D Crochet; R Grossetête; B Bach-Lijour; C Sagan; E Lecomte; B Leurent; P Brunel; J C Le Nihouannen
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Sep-Oct       Impact factor: 2.740

4.  The blood tumour barrier in intracranial tumours studied with X-ray computed tomography and positron emission tomography using 68-Ga-EDTA.

Authors:  M Mosskin; H von Holst; K Ericson; G Norén
Journal:  Neuroradiology       Date:  1986       Impact factor: 2.804

5.  Tissue compatibility of different intracranial implant materials: in-vivo and in-vitro studies.

Authors:  A Ammar
Journal:  Acta Neurochir (Wien)       Date:  1984       Impact factor: 2.216

6.  Tantalum markers in radiography. An assessment of tissue reactions.

Authors:  A S Aronson; N Jonsson; P Alberius
Journal:  Skeletal Radiol       Date:  1985       Impact factor: 2.199

7.  Efficacy of silver nanoparticles-impregnated external ventricular drain catheters in patients with acute occlusive hydrocephalus.

Authors:  Peter Lackner; Ronny Beer; Gregor Broessner; Raimund Helbok; Klaus Galiano; Claudia Pleifer; Bettina Pfausler; Christian Brenneis; Christian Huck; Klaus Engelhardt; Alois A Obwegeser; Erich Schmutzhard
Journal:  Neurocrit Care       Date:  2008       Impact factor: 3.210

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.