Fluid dynamic factors in tracheal pressure measurement.

H K Chang, J P Mortola.   

Abstract

Because tracheal pressure measurement generally involves the use of a cannula or an endotracheal tube, fluid dynamic factors may cause a considerable artifact. We present a theoretical explanation of the observed apparent paradox in which the resistance of a tracheal cannula or an endotracheal tube is isolation was found to exceed the resistance of the airways plus the cannula or the tube in situ. By estimating the viscous dissipation and the kinetic energy change in a conduit with sudden variation of cross-sectional area, a predictive model is derived. The predictions are verified by a series of in vitro experiments with both steady and oscillatory flows. The experiments showed that the pressure recorded from the sidearm of a tracheal cannula or endotracheal tube contains an error which, in general, increased with the mean Reynolds' number of the through flow and also depends on the diameter ratio between the trachea and the tube or cannula, the position of the pressure tap, and the frequency of ventilation. When feasible, direct measurement with a needle in the trachea is suggested as a way to avoid the possible artifacts arising from the use fo a side tap of the cannula. Theoretical considerations, as well as in vitro and animal experiments, indicate that adding a properly chosen expansion to the tracheal cannula makes it possible to alter inspiratory and expiratory pressures selectively. This device may prove useful in control of breathing studies.

Entities:  

Mesh:

Year:  1981        PMID: 7263418     DOI: 10.1152/jappl.1981.51.1.218

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  5 in total

1.  Combined conventional ventilation with high frequency oscillation in neonates.

Authors:  E W Hoskyns; A D Milner; I E Hopkin
Journal:  Eur J Pediatr       Date:  1991-03       Impact factor: 3.183

2.  Flow and volume dependence of rat airway resistance during constant flow inflation and deflation.

Authors:  Alessandro Rubini; Emanuele Luigi Carniel; Andrea Parmagnani; Arturo Nicola Natali
Journal:  Lung       Date:  2011-08-28       Impact factor: 2.584

3.  A comparison of endotracheal tube compensation techniques for the measurement of respiratory mechanical impedance at low frequencies.

Authors:  Andrea F Cruz; Jacob Herrmann; Carlos R R Carvalho; David W Kaczka
Journal:  J Clin Monit Comput       Date:  2021-12-15       Impact factor: 1.977

4.  The Effects of Prone with Respect to Supine Position on Stress Relaxation, Respiratory Mechanics, and the Work of Breathing Measured by the End-Inflation Occlusion Method in the Rat.

Authors:  Alessandro Rubini
Journal:  Lung       Date:  2015-11-19       Impact factor: 2.584

5.  Effects of the pneumoperitoneum and Trendelenburg position on respiratory mechanics in the rats by the end-inflation occlusion method.

Authors:  Alessandro Rubini; Daniele Del Monte; Vincenzo Catena
Journal:  Ann Thorac Med       Date:  2012-10       Impact factor: 2.219

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.