Circulatory and ventilatory effects of hypervolaemia in artificially ventilated piglets.

S Lindahl.   

Abstract

The influence of hypervolaemia upon circulation and pulmonary ventilation was studied in six piglets (body weights 8.5-10.5 kg). A new functional principle for artificial ventilation was used. The alveolar ventilation was unchanged at normovolaemia and hypervolaemia. Arterial blood gases were sampled and end-tidal carbon dioxide concentrations were measured continuously. Central circulation was followed by pressure recordings and an electromagnetic flow meter for cardiac output measurements. Mean values +/- SEM of end-inspiratory tracheal pressures increased from 0.98 +/- 0.06 kPa at normovolaemia to 1.57 +/- 0.06 kPa at hypervolaemia (p less than 0.02). In all animals total compliance decreased (p less than 0.02). Simultaneously the insufflation time for the tidal volume decreased by 13 per cent (p less than 0.05). Arterial oxygen tensions decreased from 8.5 +/- 0.48 kPa to 7.0 +/- 0.77 kPa (p less than 0.05). During hypervolaemia aortic pressures increased from 13.1 +/- 1.3 kPa to 14.9 +/- 0.8 kPa (p less than 0.05), pulmonary artery pressures from 2.8 +/- 0.33 kPa to 5.0 +/- 0.53 kPa (p less than 0.02) and cardiac output from 1.07 +/- 0.17 1 . min-1 to 1.5 +/- 0.19 1 . min-1 (p less than 0.02). The stroke work for the right heart increased by 74 per cent (p less than 0.02) and for the left heart by 62 per cent (p less than 0.02). Pulmonary vascular resistance was unchanged, while systemic vascular resistance was significantly decreased (p less than 0.05). The positive effect upon systemic circulation gained by the use of excessive fluid therapy resulted in an overcirculation within the lungs which reduced pulmonary ventilation. This reduction could most probably be related to a closure of terminal airways secondary to lung hyperperfusion, increasing the pulmonary shunt.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7260714     DOI: 10.1007/BF03007803

Source DB:  PubMed          Journal:  Can Anaesth Soc J        ISSN: 0008-2856


  27 in total

1.  Artificial ventilation by respirator for newborn infants during anaesthesia.

Authors:  L G OKMIAN
Journal:  Acta Anaesthesiol Scand       Date:  1963       Impact factor: 2.105

2.  Effect of abdominal operations on total lung capacity and its subdivisions.

Authors:  A R ANSCOMBE; R S BUXTON
Journal:  Br Med J       Date:  1958-07-12

3.  Artificial ventilation in children during anaesthesia using a tidal volume ventilator.

Authors:  S Lindahl; L Okmian; D Thomson
Journal:  Acta Anaesthesiol Scand       Date:  1979-12       Impact factor: 2.105

4.  Balanced electrolyte solutions: experimental and clinical studies.

Authors:  R W Virgilio; D E Smith; C K Zarins
Journal:  Crit Care Med       Date:  1979-03       Impact factor: 7.598

5.  Critique of crystalloid versus colloid therapy in shock and shock lung.

Authors:  W C Shoemaker; C J Hauser
Journal:  Crit Care Med       Date:  1979-03       Impact factor: 7.598

6.  Small-airways function in myocardial infarction.

Authors:  C A Hales; H Kazemi
Journal:  N Engl J Med       Date:  1974-04-04       Impact factor: 91.245

7.  Treatment of respiratory failure in nonthoracic trauma.

Authors:  H Pontoppidan
Journal:  J Trauma       Date:  1968-09

8.  Influence of an end inspiratory pause on pulmonary ventilation, gas distribution, and lung perfusion during artificial ventilation.

Authors:  S Lindahl
Journal:  Crit Care Med       Date:  1979-12       Impact factor: 7.598

9.  Pigs in the laboratory.

Authors:  L K Bustad
Journal:  Sci Am       Date:  1966-06       Impact factor: 2.142

10.  Correlation of changes in body weight and pulmonary vascular pressures with lung water accumulation during fluid overload.

Authors:  R H Demling
Journal:  Crit Care Med       Date:  1979-04       Impact factor: 7.598

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.