Literature DB >> 7247396

Automation of the Limulus amoebocyte lysate test by using the Abbott MS-2 microbiology system.

J H Jorgensen, G A Alexander.   

Abstract

A rapid, automated method for the performance of the Limulus amoebocyte lysate endotoxin assay has been developed by using the Abbott MS-2 Microbiology System. This instrument automatically determines sequential changes in the optical density of up to 176 samples at 1- or 5-min increments during a 1-h assay period. Graphic representation of optical density changes can be viewed on a cathode-ray tube or reproduced by using a hard-copy printer. Limulus amoebocyte lysate preparations that were obtained from different commercial producers and that had similar endotoxin sensitivities by the conventional gelation method varied somewhat in reactivity when determinations were based upon rate changes in optical density. Lysates from Associates of Cape Cod, Difco Laboratories, and M. A. Bioproducts were the most readily adaptable to the MS-2 System. Use of the MS-2 system increased the sensitivity of these preparations from 60- to 250-fold, and as little as 1 pg/ml was detected. Adaptation of the MS-2 instrument for this purpose provides an objective, reproducible, automated method for the performance of Limulus amoebocyte lysate tests on a variety of fluids.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7247396      PMCID: PMC243917          DOI: 10.1128/aem.41.6.1316-1320.1981

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  22 in total

1.  Rapid determination of bacteriological water quality by using limulus lysate.

Authors:  T M Evans; J E Schillinger; D G Stuart
Journal:  Appl Environ Microbiol       Date:  1978-02       Impact factor: 4.792

2.  Application of LAL for detection of endotoxin in antibiotic preparations.

Authors:  S J Harrison; K Tsuji; R M Enzinger
Journal:  Prog Clin Biol Res       Date:  1979

3.  Comparison of Limulus assay, standard plate count, and total coliform count for microbiological assessment of renovated wastewater.

Authors:  J H Jorgensen; J C Lee; G A Alexander; H W Wolf
Journal:  Appl Environ Microbiol       Date:  1979-05       Impact factor: 4.792

4.  Comparison of limulus amebocyte lysates and correlation with the United States Pharmacopeial pyrogen test.

Authors:  R E Wachtel; K Tsuji
Journal:  Appl Environ Microbiol       Date:  1977-06       Impact factor: 4.792

5.  Letter: Slide test as a micromethod of a modified Limulus endotoxin test.

Authors:  P Frauch
Journal:  J Pharm Sci       Date:  1974-05       Impact factor: 3.534

6.  Limulus lysate test for gram-negative bacterial meningitis. Bedside application.

Authors:  S Ross; W Rodriguez; G Controni; G Korengold; S Watson; W Khan
Journal:  JAMA       Date:  1975-09-29       Impact factor: 56.272

7.  Evaluation of the MS-2 system for rapid identification of Enterobacteriaceae.

Authors:  A W McCracken; W J Martin; L R McCarthy; D A Schwab; B H Cooper; N G Helgeson; S Prowant; J Robson
Journal:  J Clin Microbiol       Date:  1980-11       Impact factor: 5.948

8.  Rapid detection of gram-negative bacterial meningitis by the limulus lysate test.

Authors:  R Nachum; A Lipsey; S E Siegel
Journal:  N Engl J Med       Date:  1973-11-01       Impact factor: 91.245

9.  Rapid diagnosis of gram-negative bacterial meningitis by the Limulus endotoxin assay.

Authors:  J H Jorgensen; J C Lee
Journal:  J Clin Microbiol       Date:  1978-01       Impact factor: 5.948

10.  Rapid presumptive diagnosis of gonococcal cervicitis by the limulus lysate assay.

Authors:  V A Spagna; R B Prior; R L Perkins
Journal:  Am J Obstet Gynecol       Date:  1980-07-01       Impact factor: 8.661

View more
  4 in total

1.  Single-step, chromogenic Limulus amebocyte lysate assay for endotoxin.

Authors:  G K Lindsay; P F Roslansky; T J Novitsky
Journal:  J Clin Microbiol       Date:  1989-05       Impact factor: 5.948

2.  The Limulus Amoebocyte Lysate test: detection of endotoxin in plasma of swine and cattle. I. In vitro investigations.

Authors:  K Mortensen; M Binder
Journal:  Acta Vet Scand       Date:  1985       Impact factor: 1.695

3.  Rapid detection of significant bacteriuria by use of an automated Limulus amoebocyte lysate assay.

Authors:  J H Jorgensen; G A Alexander
Journal:  J Clin Microbiol       Date:  1982-09       Impact factor: 5.948

Review 4.  Endotoxemia: methods of detection and clinical correlates.

Authors:  J C Hurley
Journal:  Clin Microbiol Rev       Date:  1995-04       Impact factor: 26.132

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.