Resolution and accuracy in two dimensional echocardiography.

L A Latson, J P Cheatham, H P Gutgesell.   

Abstract

The resolution and accuracy of commercially available two dimensional echocardiographic systems were tested by imaging two types of in vitro test objects. One consisted of a series of fine parallel threads spaced at known intervals and the other was a tissue phantom in which a series of holes of known size had been cut. The echocardiographic systems tested included a mechanical single element sector scanner, a three element rotary sector scanner and a phased array system. Azimuthal resolution, lateral resolution and accuracy of horizontal distance measurements were assessed at depths of 2 and 6 cm. For each system, azimuthal resolution was better than lateral resolution, especially when assessed with use of the parallel threads. When the tissue phantom was imaged, the best resolution (2 mm in azimuthal and lateral directions) was obtained with the highest frequency transducer tested (3.5 MHz). The apparent size of a tissue defect was sensitive to gain settings, especially at a depth of 2 cm with lower frequency transducers; at a depth of 6 cm, echographic measurements of defect size were accurate to within 2.5 mm. Recent applications of two dimensional echocardiography require near the apparent limits of current equipment. It is recommended that the highest frequency transducer and lowest possible gain settings be used in these situations.

Mesh:

Year:  1981        PMID: 7246432     DOI: 10.1016/0002-9149(81)90578-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

Review 1.  [Perioperative echocardiography: basic principles].

Authors:  M Nowak; P Rosenberger; T W Felbinger; A E Götz; S K Shernan; K Unertl; H K Eltzschig
Journal:  Anaesthesist       Date:  2006-03       Impact factor: 1.041

2.  Direct visualization of aorto-coronary bypass grafts by two-dimensional echocardiography: a new clinical application.

Authors:  I Sheiban; G Trevi; D Casarotto; A Marini; P Benussi; R Accardi; M Zanini; P Pugliese; L Bullian; G Montresor
Journal:  Cardiovasc Intervent Radiol       Date:  1988       Impact factor: 2.740

3.  Assessment of left atrial dimensions by cross sectional echocardiography in patients with mitral valve disease.

Authors:  F Loperfido; F Pennestri; A Digaetano; E Scabbia; P Santarelli; R Mongiardo; G Schiavoni; E Coppola; U Manzoli
Journal:  Br Heart J       Date:  1983-12

4.  How accurate is the ultrasonic estimation of ventricular septal defect size?

Authors:  Z Kececioglu-Draelos; S J Goldberg; D J Sahn
Journal:  Pediatr Cardiol       Date:  1982       Impact factor: 1.655

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.