Literature DB >> 7235880

[The experimental measurement of torque and axial force of 6.5 mm ASIF lag screws in fixation of femoral neck fractures (author's transl)].

N Schwarz, J Newald.   

Abstract

An experimental study was undertaken to evaluate the torque and axial force of the 6.5 mm ASIF lag screw implanted in the femoral neck after a subcapital osteotomy. The experiments were carried out on autopsied bones of more than 60 years of age. The average torque was 204 cmN, the screws in the upper half of the femoral head showing a higher torque than those in the lower half. The axial tension was measured by strain gauge transducer. Depending on the length of the thread of the screw (16 or 32 mm) the average tension reaches 1162 N or 1960 N. By tightening the screw until the impression of optimum fit is obtained, 70% of the maximum axial force is reached. It can therefore be estimated that at the beginning an interfragmentary pressure of 4000 to 8000 N is exerted on a medial femoral neck fracture fixed by four ASIF lag screws.

Entities:  

Mesh:

Year:  1981        PMID: 7235880     DOI: 10.1007/bf00389712

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  10 in total

1.  [Better stabilisation of the femoral neck fractures with drawing-screw-osteosynthesis according to AO principle (author's transl)].

Authors:  M Forgon
Journal:  Arch Orthop Unfallchir       Date:  1975

2.  [Measurement of torque in bone screws during surgery].

Authors:  J Brennwald; P Matter; C Arx; J Cordey; S M Perren
Journal:  Z Unfallmed Berufskr       Date:  1975

3.  [Biomechanic researches of maximum initial tension forces of bone screws on various bone sections (author's transl)].

Authors:  K Diehl; U Hanser; W Hort; H Mittelmeier
Journal:  Arch Orthop Unfallchir       Date:  1974

4.  [Piezoelectric and tension optical studies on the biomechanics of screw osteosynthesis].

Authors:  H Mittelmeier
Journal:  Z Orthop Ihre Grenzgeb       Date:  1972-12

5.  [Experimental studies on the mechanical load capacity of femoral head spongiosa as a requirement for axial compression osteosynthesis after femoral neck fractures].

Authors:  H J Kaessmann; G Hopf; H Koch; D Lattermann; P Stankovic; J Hardt; W Kunith
Journal:  Arch Orthop Unfallchir       Date:  1972

6.  [Improvement of osteosynthetic stability after femoral neck fracture by the axial compression screw].

Authors:  H J Kaessmann; G Hopf; H Koch; D Lattermann; P Stankovic; J Hardt; W Kunith
Journal:  Arch Orthop Unfallchir       Date:  1972

7.  [Studies on pressure osteosynthesis of medial femoral neck fractures. Theoretical and experimental studies of postulatses on the use of pressure in biological healing of femoral neck fractures. II. Statistical postulates on the application of pressure. Pressure needed for stabilization].

Authors:  H Buse
Journal:  Arch Orthop Unfallchir       Date:  1971

8.  [Compression osteosynthesis of median femoral neck fractures. Theoretical and experimental studies on the requirements for the use of compression in the biological healing of femoral neck fractures. I. Statistical analysis of the magnitude of mechanical stress in the femoral neck cross section].

Authors:  H Buse
Journal:  Arch Orthop Unfallchir       Date:  1971

9.  [Mechanical conditions in osteosynthesis performed with 3 spongiosa traction screws according to the A-O method after fracture of neck of femur. A comparative study in osteosynthesis using a 130 degrees angular plate and a traction screw (author's transl)].

Authors:  H Zilch; K Naseband
Journal:  Aktuelle Traumatol       Date:  1980-04

10.  [Results of treatment of fractures of the femoral neck by compression fixation (author's transl)].

Authors:  N Schwarz
Journal:  Unfallheilkunde       Date:  1979-07
  10 in total
  1 in total

1.  [Comparative results of compression and non-compression operation methods following medial femoral neck fracture].

Authors:  H Resch; G Sperner
Journal:  Unfallchirurgie       Date:  1987-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.