Cardiac arrhythmias. Frequency during fiberoptic bronchoscopy and correlation with hypoxemia.

A S Katz, E L Michelson, J Stawicki, F D Holford.   

Abstract

To evaluate the occurrence of ECG abnormalities during fiberoptic bronchoscopy in relation to specific stages of the procedure and to hypoxemia, we prospectively studied 50 hospitalized patients aged 53 +/- 18 years (mean +/- SD) who were undergoing bronchoscopy by continuously monitoring cardiac rhythm with a continuous two-channel ECG recorder and oxygen saturation by using ear oximetry. Major disturbances of cardiac rhythm (ie, atrial, ventricular, or both) developed in 20 (40%) patients. Ventricular arrhythmias were recorded in ten patients (20%) and occurred with greatest frequency during passage of the bronchoscope through the vocal cords in five of these patients. Atrial arrhythmias were detected in 16 patients (32%), but their occurrence did not correlate closely with any one stage of the procedure. Arrhythmias were most frequent in association with periods of maximum oxygen desaturation in 12 of these 20 patients. Oxygen desaturation persisted for greater than one hour after bronchoscopy in 34 (68%) of 50 subjects. Notably, no correlation was observed between the frequency of arrhythmias during bronchoscopy and patients' age, sex, prior medications, or preexisting cardiac or pulmonary disorders. In no case was an ECG abnormality associated with adverse clinical sequelae.

Entities:  

Mesh:

Year:  1981        PMID: 7224740

Source DB:  PubMed          Journal:  Arch Intern Med        ISSN: 0003-9926


  8 in total

1.  British Thoracic Society guidelines on diagnostic flexible bronchoscopy.

Authors: 
Journal:  Thorax       Date:  2001-03       Impact factor: 9.139

Review 2.  Sedation for fibreoptic bronchoscopy.

Authors:  M P Shelley; P Wilson; J Norman
Journal:  Thorax       Date:  1989-10       Impact factor: 9.139

3.  Arterial oxygen saturation during bronchography via the fibreoptic bronchoscope.

Authors:  J M Goldman; D C Currie; A D Morgan; J V Collins
Journal:  Thorax       Date:  1987-09       Impact factor: 9.139

4.  Safety of research bronchoscopy in critically ill patients.

Authors:  Sarah E W Prebil; Joel Andrews; Sushma K Cribbs; Greg S Martin; Annette Esper
Journal:  J Crit Care       Date:  2014-06-13       Impact factor: 3.425

5.  Can fiberoptic bronchoscopy be applied to critically ill patients treated with noninvasive ventilation for acute respiratory distress syndrome? Prospective observational study.

Authors:  Pervin Korkmaz Ekren; Burcu Basarik Aydogan; Alev Gurgun; Mehmet Sezai Tasbakan; Feza Bacakoglu; Stefano Nava
Journal:  BMC Pulm Med       Date:  2016-05-31       Impact factor: 3.317

6.  Effectiveness and Safety of High-Flow Nasal Cannula Oxygen Delivery during Bronchoalveolar Lavage in Acute Respiratory Failure Patients.

Authors:  Eun Jin Kim; Chi Young Jung; Kyung Chan Kim
Journal:  Tuberc Respir Dis (Seoul)       Date:  2018-06-19

7.  High-Flow vs. Low-Flow Nasal Cannula in Reducing Hypoxemic Events During Bronchoscopic Procedures: A Systematic Review and Meta-Analysis.

Authors:  Fotios Sampsonas; Vasileios Karamouzos; Theodoros Karampitsakos; Ourania Papaioannou; Matthaios Katsaras; Maria Lagadinou; Eirini Zarkadi; Elli Malakounidou; Dimitrios Velissaris; Grigorios Stratakos; Argyrios Tzouvelekis
Journal:  Front Med (Lausanne)       Date:  2022-02-24

8.  ECG Abnormalities in Patients with Acute Exacerbation of Bronchiectasis and Factors Associated with High Probability of Abnormality.

Authors:  Fatima Alhamed Alduihi
Journal:  Pulm Med       Date:  2021-07-05