Literature DB >> 7222263

Analysis of the error in measurement of ultrasound speed in tissue due to waveform deformation by frequency-dependent attenuation.

M Ragozzino.   

Abstract

A systematic error exists in measurement of ultrasound speed in tissue with pulse methods. Frequency-dependent attenuation distorts the incident waveform as it passes through tissue causing an error in determination of speed when the time interval between fixed points on the incident and transmitted waveforms is measured. Two equations have been derived for a generalized pulse in a non-dispersive medium that enable calculation of this error when the peaks of the waveforms or the zero-crossings are used as reference points in the speed measurement. The errors have been calculated for measurement of speed in muscle, liver and fat for path lengths of 5, 10, an 15 cm for two incident pulse shapes. In general, the magnitude of this error is small compared to the biological variation, but may be significant compared to experimental error.

Mesh:

Year:  1981        PMID: 7222263     DOI: 10.1016/0041-624x(81)90084-6

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  6 in total

Review 1.  Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-10-16       Impact factor: 2.725

2.  Ultrasound transmission technique as a potential tool for physical evaluation of monolithic matrix tablets.

Authors:  M A Hakulinen; J Pajander; J Leskinen; J Ketolainen; B van Veen; K Niinimäki; K Pirskanen; A Poso; R Lappalainen
Journal:  AAPS PharmSciTech       Date:  2008-01-09       Impact factor: 3.246

3.  Measurements of phase velocity and group velocity in human calcaneus.

Authors:  K A Wear
Journal:  Ultrasound Med Biol       Date:  2000-05       Impact factor: 3.694

4.  Relationships of ultrasonic backscatter with ultrasonic attenuation, sound speed and bone mineral density in human calcaneus.

Authors:  K A Wear; A P Stuber; J C Reynolds
Journal:  Ultrasound Med Biol       Date:  2000-10       Impact factor: 3.694

5.  Characterization of trabecular bone using the backscattered spectral centroid shift.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-04       Impact factor: 3.267

6.  The effects of frequency-dependent attenuation and dispersion on sound speed measurements: applications in human trabecular bone.

Authors:  K A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2000       Impact factor: 3.267

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.