Literature DB >> 7212427

In vivo and in vitro measurement of tendon strain in the horse.

F K Lochner, D W Milne, E J Mills, J J Groom.   

Abstract

Strains gauges were applied to the superficial flexor tendon, deep flexor tendon, and suspensory ligament of sound adult horses. Maximum tendon strain occurred during full weight bearing while walking, when the forelimb was perpendicular to the group surface. There was decrease in tendon strain with increase in hoof angle for the deep digital flexor, but no change in tendon strain for the superficial digital flexor and suspensory ligament with changing hoof angle. At physiologic rates of strain, tendons were able to withstand large loads without yielding. Load strain curves developed in vitro indicated that during walking, the deep digital flexor was calculated to load to 416.8 kg; the superficial flexor tendon to 362.9 kg; and the suspensory ligament to 172.4 kg. This study shows that in the horse, strain in flexor tendons during walking was in excess of 5%, indicating strains within the visco-elastic range.

Entities:  

Mesh:

Year:  1980        PMID: 7212427

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  7 in total

1.  Strain-induced damage reduces echo intensity changes in tendon during loading.

Authors:  Sarah Duenwald-Kuehl; Roderic Lakes; Ray Vanderby
Journal:  J Biomech       Date:  2012-04-25       Impact factor: 2.712

2.  Shear loads induce cellular damage in tendon fascicles.

Authors:  Jaclyn Kondratko-Mittnacht; Roderic Lakes; Ray Vanderby
Journal:  J Biomech       Date:  2015-06-26       Impact factor: 2.712

3.  Force- and moment-generating capacities of muscles in the distal forelimb of the horse.

Authors:  Nicholas A T Brown; Marcus G Pandy; Christopher E Kawcak; C Wayne McIlwraith
Journal:  J Anat       Date:  2003-07       Impact factor: 2.610

4.  Mechanical compromise of partially lacerated flexor tendons.

Authors:  Jaclyn Kondratko; Sarah Duenwald-Kuehl; Roderic Lakes; Ray Vanderby
Journal:  J Biomech Eng       Date:  2013-01       Impact factor: 2.097

5.  Evolutionary loss of foot muscle during development with characteristics of atrophy and no evidence of cell death.

Authors:  Mai P Tran; Rio Tsutsumi; Joel M Erberich; Kevin D Chen; Michelle D Flores; Kimberly L Cooper
Journal:  Elife       Date:  2019-10-15       Impact factor: 8.140

6.  Biplanar High-Speed Fluoroscopy of Pony Superficial Digital Flexor Tendon (SDFT)-An In Vivo Pilot Study.

Authors:  Franziska C Wagner; Kerstin Gerlach; Sandra M Geiger; Claudia Gittel; Peter Böttcher; Christoph K W Mülling
Journal:  Vet Sci       Date:  2021-05-27

7.  In vivo measurements of flexor tendon and suspensory ligament forces during trotting using the thoroughbred forelimb model.

Authors:  Toshiyuki Takahashi; Kazutaka Mukai; Hajime Ohmura; Hiroko Aida; Atsushi Hiraga
Journal:  J Equine Sci       Date:  2014-04-22
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.