Endemic rate of fluid contamination and related septicemia in arterial pressure monitoring.

D G Maki, C A Hassemer.   

Abstract

Contamination of the fluid within intra-arterial infusions used for hemodynamic monitoring has produced epidemic bacteremias, but little data exist on endemic rates of contamination and related septicemia. We prospectively studied 102 intra-arterial infusions used in 56 high-risk patients who required prolonged monitoring. During the study, administration sets were changed every 48 hours, but transducer chamber-domes and continuous flow devices were used until the intra-arterial infusion was discontinued. Cultures were obtained from the transducer-transducer chamber-dome interface and of fluid in the transducer chamber-dome of the 102 intra-arterial infusions; 12 (11.8 percent) showed contamination of transducer chamber-dome fluid, in 8 cases (7.8 percent) associated with concordant bacteremia. In each bacteremia, transducer chamber-dome fluid contained 1 to greater than 10(5) (median, 10(4)) cfu/ml. Four bacteremias are considered definitely related and four, possibly related, to the intra-arterial infusion. In all 12 contaminated intra-arterial infusions and with all eight bacteremias, the transducer chamber-dome had been used for more than two days (P = 0.006). No concordant contamination of transducer-transducer chamber-dome interfaces was identified. (1) Intra-arterial infusions for pressure monitoring cause sporadic septicemias endemically. (2) With prolonged monitoring, transducer chamber-domes and continuous flow devices should be replaced at periodic intervals, ideally with the administration set, every 48 hours; since implementing this policy, only three contaminated intra-arterial infusions and no related septicemias have been detected in 53 intra-arterial infusions monitored over our months (P = 0.02).

Entities:  

Mesh:

Year:  1981        PMID: 7211907     DOI: 10.1016/0002-9343(81)90604-5

Source DB:  PubMed          Journal:  Am J Med        ISSN: 0002-9343            Impact factor:   4.965


  8 in total

1.  Summary of recommendations: Guidelines for the Prevention of Intravascular Catheter-related Infections.

Authors:  Naomi P O'Grady; Mary Alexander; Lillian A Burns; E Patchen Dellinger; Jeffrey Garland; Stephen O Heard; Pamela A Lipsett; Henry Masur; Leonard A Mermel; Michele L Pearson; Issam I Raad; Adrienne G Randolph; Mark E Rupp; Sanjay Saint
Journal:  Clin Infect Dis       Date:  2011-05       Impact factor: 9.079

2.  Guidelines for the prevention of intravascular catheter-related infections.

Authors:  Naomi P O'Grady; Mary Alexander; Lillian A Burns; E Patchen Dellinger; Jeffrey Garland; Stephen O Heard; Pamela A Lipsett; Henry Masur; Leonard A Mermel; Michele L Pearson; Issam I Raad; Adrienne G Randolph; Mark E Rupp; Sanjay Saint
Journal:  Clin Infect Dis       Date:  2011-04-01       Impact factor: 9.079

3.  Nosocomial infections associated with long-term radial artery cannulation.

Authors:  O Leroy; V Billiau; C Beuscart; C Santre; C Chidiac; C Ramage; Y Mouton
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

4.  Cutaneous bacterial colonization, modalities of chemotherapeutic infusion, and catheter-related bloodstream infection in totally implanted venous access devices.

Authors:  L Laurenzi; S Natoli; C Benedetti; M E Marcelli; W Tirelli; L DiEmidio; E Arcuri
Journal:  Support Care Cancer       Date:  2004-11       Impact factor: 3.603

5.  Noninvasive ventilation for patients near the end of life: what do we know and what do we need to know?

Authors:  William J Ehlenbach; J Randall Curtis
Journal:  Crit Care Med       Date:  2008-03       Impact factor: 7.598

6.  Septicaemia in a medical intensive care unit. Clinical, biochemical and microbiological data of 109 cases.

Authors:  E Domínguez de Villota; A Algora; J J Rubio; M Roig; J M Mosquera; P Galdos; V Díez-Balda
Journal:  Intensive Care Med       Date:  1983       Impact factor: 17.440

7.  The pathogenesis of catheter-related bloodstream infection with noncuffed short-term central venous catheters.

Authors:  Nasia Safdar; Dennis G Maki
Journal:  Intensive Care Med       Date:  2003-11-26       Impact factor: 17.440

Review 8.  Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine.

Authors:  Bernd Scheer; Azriel Perel; Ulrich J Pfeiffer
Journal:  Crit Care       Date:  2002-04-18       Impact factor: 9.097

  8 in total