Film dosimetry of megavoltage photon beams: a practical method of isodensity-to-isodose curve conversion.

J F Williamson, F M Khan, S C Sharma.   

Abstract

The central problems of photon beam film dosimetry are the dependence of film response upon photon energy, processing conditions, and film plane orientation. We have overcome these problems by accurately fitting the depth-dependent sensitometric curve of Kodak XV-2 film (exposed parallel to beam axis) to the equation OD(D,d) = ODs(1 - exp [- alpha 0[1 + beta(d-dm)]D]) where OD(D,d) is the optical density for dose D at depth d. ODs, alpha 0, and beta are constants characteristic of the film and beam energy but are independent of field size. Only central axis depth dose data for a single field are required to determine their values. A computer program based upon this equation has been written which successfully generates single field isodose curves from film data for a variety of field sizes (including wedged fields) with an accuracy of +/- 3%. Data are presented for 60Co, and 4 and 10 MV x rays.

Entities:  

Mesh:

Year:  1981        PMID: 7207433     DOI: 10.1118/1.594913

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Analysis of variation in calibration curves for Kodak XV radiographic film using model-based parameters.

Authors:  Shu-Hui Hsu; Ravi Kulasekere; Peter L Roberson
Journal:  J Appl Clin Med Phys       Date:  2010-08-05       Impact factor: 2.102

2.  Ion chamber measurements of transverse gamma knife beam profiles.

Authors:  Morris I Bank
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

3.  Comparison of EBT and EBT3 RadioChromic Film Usage in Parotid Cancer Radiotherapy.

Authors:  M T Bahreyni Toossi; F Khorshidi; M Ghorbani; N Mohamadian; D Davenport
Journal:  J Biomed Phys Eng       Date:  2016-03-01

4.  Skin Dosimetry in Radiotherapy of Breast Cancer: a Comparison between EBT and EBT3 Radiochromic Films.

Authors:  M T Bahreyni Toosi; N Mohamadian; M Ghorbani; F Khorshidi; F Akbari; C Knaup
Journal:  J Biomed Phys Eng       Date:  2016-06-01

5.  The use of extended dose range film for dosimetric calibration of a scanning liquid-filled ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak; Paul Reich
Journal:  J Appl Clin Med Phys       Date:  2006-05-15       Impact factor: 2.102

6.  Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons.

Authors:  Paule M Charland; Indrin J Chetty; Shigeru Yokoyama; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

7.  Monte Carlo simulations of EBT3 film dose deposition for percentage depth dose (PDD) curve evaluation.

Authors:  Spencer M Robinson; Nolan Esplen; Derek Wells; Magdalena Bazalova-Carter
Journal:  J Appl Clin Med Phys       Date:  2020-11-06       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.