Steady flow in a model of human central airways.

A S Slutsky, G G Berdine, J M Drazen.   

Abstract

We studied the pressure-flow relationships and flow distribution under steady conditions in a model of human central airways, over a range of tracheal Reynolds' numbers (350-30,000) by using air or helium. We found that the Moody diagram [log coefficient of friction CF = delta P/[1/2 rho (V2/A2)] vs. log Reynolds' number (Re)] had a slope of -1 for Re less than 500, a slope 0 for Re greater than 10,000, and slopes between -1 and 0 for 500 less than or equal to Re less than or equal to 10,000. The distribution of flow among branches was dependent on tracheal Reynolds' number so that, as tracheal Reynolds' number increased, the upper lobes received proportionally less of the total flow than the lower lobes. Because the airways in the upper lobes generally had greater branching angles than those in the lower lobes, this result was consistent with the hypothesis that the effective resistances introduced by branching angles was flow dependent, increasing proportionally more the greater the angle.

Entities:  

Mesh:

Year:  1980        PMID: 7204164     DOI: 10.1152/jappl.1980.49.3.417

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  5 in total

1.  High-frequency oscillatory pressure/flow relationship in the airways of laryngo-tracheo-bronchial tree casts.

Authors:  A Ben Jebria; M L Choukroun; Z Tabka; J S Ultman
Journal:  Med Biol Eng Comput       Date:  1988-09       Impact factor: 2.602

2.  Linear-lumped-parameter modeling of pulmonary impedance in monkeys.

Authors:  C D Wegner; A C Jackson; J R Gillespie
Journal:  Ann Biomed Eng       Date:  1986       Impact factor: 3.934

3.  Regional alveolar pressure during periodic flow. Dual manifestations of gas inertia.

Authors:  J L Allen; I D Frantz; J J Fredberg
Journal:  J Clin Invest       Date:  1985-08       Impact factor: 14.808

4.  Scanographic comparison of high frequency oscillation with versus without tracheal gas insufflation in acute respiratory distress syndrome.

Authors:  Spyros D Mentzelopoulos; Maria Theodoridou; Sotirios Malachias; Sotiris Sourlas; Demetrios N Exarchos; Demetrios Chondros; Charis Roussos; Spyros G Zakynthinos
Journal:  Intensive Care Med       Date:  2011-03-03       Impact factor: 17.440

5.  Comparison of high-frequency oscillation and tracheal gas insufflation versus standard high-frequency oscillation at two levels of tracheal pressure.

Authors:  Spyros D Mentzelopoulos; Sotiris Malachias; Stelios Kokkoris; Charis Roussos; Spyros G Zakynthinos
Journal:  Intensive Care Med       Date:  2010-03-16       Impact factor: 17.440

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.