Literature DB >> 7199962

The use of halothane in a patient with asymmetrical septal hypertrophy: a case report.

J A Reitan, R G Wright.   

Abstract

An elderly patient with demonstrated asymmetrical intraventricular septal hypertrophy and ventriculo-aortic pressure gradient was anaesthetized with nitrous oxide with oxygen, narcotic, and muscle relaxant for abdominal surgery. In addition to the cardiovascular variables customarily monitored, a systolic time interval (STI) measured from the Q wave of the ECG to the foot of the radial pulse (the QF interval) was calculated in milliseconds beat-to-beat by a computer. With anaesthesia, and particularly following the beginning of operation, the QF interval lengthened as an indication of either decreased cardiac inotropy or increased pressure gradient across the aortic outflow tract. When halothane 0.25 per cent was added to the anaesthetic mixture, the QF interval shortened by about 20 milliseconds without an observed change in direct arterial pressure. Since halothane is a cardiac depressant and normally lengthens the STI, it apparently relaxed the muscular stenosis of the ventricular outflow tract and reduced the pressure gradient and, subsequently, the QF interval. By measuring cardiovascular function with this STI, the beneficial action of cardiac depression from low-dose halothane was observed, which would have escaped detection by common monitoring indices.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7199962     DOI: 10.1007/bf03007995

Source DB:  PubMed          Journal:  Can Anaesth Soc J        ISSN: 0008-2856


  4 in total

1.  IDIOPATHIC HYPERTROPHIC SUBAORTIC STENOSIS. 3. INTRAOPERATIVE STUDIES OF THE MECHANISM OF OBSTRUCTION AND ITS HEMODYNAMIC CONSEQUENCES.

Authors:  G E PIERCE; A G MORROW; E BRAUNWALD
Journal:  Circulation       Date:  1964-11       Impact factor: 29.690

2.  Biventricular cineangiography in the evaluation of patients with asymmetric septal hypertrophy.

Authors:  D R Redwood; J L Scherer; S E Epstein
Journal:  Circulation       Date:  1974-06       Impact factor: 29.690

3.  Echocardiographic measurement of the left ventricular outflow gradient in idiopathic hypertrophic subaortic stenosis.

Authors:  W L Henry; C E Clark; D L Glancy; S E Epstein
Journal:  N Engl J Med       Date:  1973-05-10       Impact factor: 91.245

4.  Effect of halothane on systolic time intervals.

Authors:  J D Hasbrouck; C C Coleman
Journal:  Anesth Analg       Date:  1977 Jul-Aug       Impact factor: 5.108

  4 in total