Literature DB >> 7194796

[Transthoracic electrical impedance (author's transl)].

C Stick.   

Abstract

The measurement of transthoracic impedance is used by many authors to determine tidal volume and changes of intrathoracic fluid volume. In clinical diagnostics, too, this method has been introduced. Furthermore, the stroke volume of the heart is often said to be calculable from changes in impedance synchronous with the cardiac cycle. This paper investigates the theoretical foundations, and tries to estimate the extent by which the various measuring errors inherent in this method may falsify the results obtained. Measurements of the phase angle show that the errors occurring when using impedance instead of resistance are negligible. The determination of impedance is considerably influenced by breathing and body position. An analysis of these normally superimposing effects demonstrates the problematic nature of this method. It is shown that changes in intrathoracic fluid volume can be determined only with unchanged positioning of the electrodes, constant body position and elimination of the influence of breathing. Respiratory movements can be registered, whereas the influence of changes in the basic impedance on determining the stroke volume by impedance cardiography has not been fully researched.

Entities:  

Mesh:

Year:  1981        PMID: 7194796     DOI: 10.1007/bf00428871

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  17 in total

1.  Measurement of pleural effusion by electrical impedance.

Authors:  J C Denniston; L E Baker
Journal:  J Appl Physiol       Date:  1975-05       Impact factor: 3.531

2.  THORACIC CAGE IMPEDANCE MEASUREMENTS. TISSUE RESISTIVITY IN VIVO AND TRANSTHORACIC IMPEDANCE AT 100 KC. TECHN DOCUM REP NO. SAM-TDR-64-5.

Authors:  E KINNEN; W KUBICEK; P HILL; G TURTON
Journal:  AMD TR Rep       Date:  1964-03

3.  VOLUMETRIC DYNAMICS OF RESPIRATION AS MEASURED BY ELECTRICAL IMPEDANCE PLETHYSMOGRAPHY.

Authors:  R D ALLISON; E L HOLMES; J NYBOER
Journal:  J Appl Physiol       Date:  1964-01       Impact factor: 3.531

4.  Specific resistance of body tissues.

Authors:  C F KAY; H P SCHWAN
Journal:  Circ Res       Date:  1956-11       Impact factor: 17.367

5.  Transthoracic electrical impedance; quantitative evaluation of a non-invasive measure of thoracic fluid volume.

Authors:  R V Luepker; J R Michael; J R Warbasse
Journal:  Am Heart J       Date:  1973-01       Impact factor: 4.749

6.  Transthoracic electrical impedance variations associated with respiration.

Authors:  S Kira; Y Hukushima; S Kitamura; A Ito
Journal:  J Appl Physiol       Date:  1971-06       Impact factor: 3.531

7.  Application of impedance cardiography to study of postural stress.

Authors:  J J Smith; J E Bush; V T Wiedmeier; F E Tristani
Journal:  J Appl Physiol       Date:  1970-07       Impact factor: 3.531

8.  Transthoracic electrical impedance for the early detection of pulmonary edema.

Authors:  M Pomerantz; R Baumgartner; J Lauridson; B Eiseman
Journal:  Surgery       Date:  1969-07       Impact factor: 3.982

9.  Bioelectric impedance. New developments and clinical application.

Authors:  J M Van de Water; P A Philips; L G Thouin; L S Watanabe; R S Lappen
Journal:  Arch Surg       Date:  1971-06

10.  [Impedance plethysmography: measurements of volume changes of human limbs caused by capillary filtration (author's transl)].

Authors:  C Stick
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1981
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.