Literature DB >> 7194621

Late results of reconstruction of the right ventricular outflow tract with porcine xenografts in children.

G S Bisset, D C Schwartz, G Benzing, J Helmsworth, J T Schreiber, S Kaplan.   

Abstract

Thirty-three children, aged 2.5 to 17.5 years (mean, 8.3 years), having xenograft external conduits placed between the right ventricle and pulmonary artery were followed for 1 to 6 years postoperatively (mean, 3.5 years). There were no late deaths in the study group, and no infection of a valved conduit has been demonstrated. Twenty of these children were catheterized during the follow-up period. The gradients from the right ventricle to pulmonary artery ranged from 8 to 90 mm Hg (average, 31 mm Hg). A total of 8 patients were classified as having hemodynamically documented conduit failure, and an additional 2 patients are clinically expected to have conduit failure. This represents a total incidence of 30% xenograft conduit failure in a 6-year follow-up. Although the etiology of this dysfunction is probably multifactorial, factors such as valve size, conduit angulation, and immunological competence bear special consideration. We conclude that although valved external conduits continue to play an important role in the treatment of complex congenital heart disease, a valved conduit with greater longevity is needed for use in children.

Entities:  

Mesh:

Year:  1981        PMID: 7194621     DOI: 10.1016/s0003-4975(10)60998-8

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  Autologous tissue-fragmented extracardiac conduit with rapid, stable endothelialization due to angiogenesis.

Authors:  M Ando; Y Tomizawa; Y Noishiki; M Terada; Y Imai
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2000-03

2.  Wrapped-knitted Dacron and microporous EPTFE conduits for reconstruction of right ventricular outflow tract.

Authors:  H Matsumoto; F Miyawaki; T Takayama; K Asano
Journal:  Jpn J Surg       Date:  1985-07

3.  Preliminary experience with GORE-TEX grafting for right ventricle-pulmonary artery conduits.

Authors:  J E Molina
Journal:  Tex Heart Inst J       Date:  1986-03

4.  Outcome of 40 consecutive cases of modified Ross procedure using novel Dacron valved conduit.

Authors:  Lakshmi Kumari Sankhyan; Rajarshi Ghosh; Santosh Kumar; Sujoy Chatterjee; Sudipta Bhattachariya; Saurabhi Das; Hemant Kumar Nayak; Satyajit Bose; Srirup Chatterjee
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-07-23
  4 in total