Literature DB >> 7189869

Versatile piezoelectric driver for cell puncture.

M Fromm, P Weskamp, U Hegel.   

Abstract

A simple and versatile tool facilitating micropuncture of small cells is described which utilizes a commercial piezoelectric element made from a stacked column of monomorph ceramic discs. The device is able to advance complete input stage-electrode-assemblies with high speed and can be used in combination with conventional micromanipulators. Advancing characteristics as recorded optically at high magnification demonstrated less axial vibration, although faster action, than two other modern micropositioners driven by step motors. In biological experiments on selected tissues (Necturus gallbladder epithelium, Amphiuma renal distal tubule cells, rabbit and human corneal endothelium) the combined use of micromanipulator and piezo-stepper was, in all cases, superior to the use of a micromanipulator alone: the percentage of successful cell penetrations increased, cell potentials were stable for a longer time, and the durability of electrode-tips improved.

Entities:  

Mesh:

Year:  1980        PMID: 7189869     DOI: 10.1007/bf00589517

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  7 in total

1.  Piezoelectric Micromanipulators: Electrically operated micromanipulators add automatic high-speed movement to normal manual control.

Authors:  G W Ellis
Journal:  Science       Date:  1962-10-12       Impact factor: 47.728

2.  Micropositioner in a closed-loop control system.

Authors:  G I Connor
Journal:  IEEE Trans Biomed Eng       Date:  1973-03       Impact factor: 4.538

3.  Direct measurements of membrane potential and membrane resistance of human red cells.

Authors:  U V Lassen; O Sten-Knudsen
Journal:  J Physiol       Date:  1968-04       Impact factor: 5.182

4.  Piezoelectric driving device for glass capillary microelectrodes.

Authors:  J T Tupper; R Rikmenspoel
Journal:  Rev Sci Instrum       Date:  1969-06       Impact factor: 1.523

5.  The potential and resistance profile of Necturus gallbladder cells.

Authors:  K Suzuki; E Frömter
Journal:  Pflugers Arch       Date:  1977-10-19       Impact factor: 3.657

6.  Penetration of cells membrane by the piezoelectric driver.

Authors:  J Prazma
Journal:  Experientia       Date:  1978-10-15

7.  Intracellular potentials of isolated rabbit and human corneal endothelium.

Authors:  M Wiederholt; M Koch
Journal:  Exp Eye Res       Date:  1978-11       Impact factor: 3.467

  7 in total
  9 in total

1.  Membrane potentials of individual cells of isolated gastric glands of rabbit.

Authors:  T Schettino; M Köhler; E Frömter
Journal:  Pflugers Arch       Date:  1985-09       Impact factor: 3.657

2.  Adaptation of the jejunal mucosa in the experimental blind loop syndrome: changes in paracellular conductance and tight junction structure.

Authors:  J D Schulzke; M Fromm; C J Bentzel; H Menge; E O Riecken
Journal:  Gut       Date:  1987       Impact factor: 23.059

3.  Protamine alters structure and conductance of Necturus gallbladder tight junctions without major electrical effects on the apical cell membrane.

Authors:  C J Bentzel; M Fromm; C E Palant; U Hegel
Journal:  J Membr Biol       Date:  1987       Impact factor: 1.843

4.  Alpha and beta-adrenergic mediation of membrane potential changes and metabolism in rat brown adipose tissue.

Authors:  L Girardier; G Schneider-Picard
Journal:  J Physiol       Date:  1983-02       Impact factor: 5.182

5.  Piezoelectric translator. A simple and inexpensive device to move microelectrodes and micropipettes small distances rapidly.

Authors:  W J Lederer
Journal:  Pflugers Arch       Date:  1983-09       Impact factor: 3.657

6.  Properties of the lumen membrane of the cortical thick ascending limb of Henle's loop of rabbit kidney.

Authors:  R Greger; E Schlatter
Journal:  Pflugers Arch       Date:  1983-03       Impact factor: 3.657

7.  Cell puncturing with a step motor driven manipulator with simultaneous measurement of displacement.

Authors:  U Sonnhof; R Förderer; W Schneider; H Kettenmann
Journal:  Pflugers Arch       Date:  1982-01       Impact factor: 3.657

8.  Epithelial and subepithelial contributions to transmural electrical resistance of intact rat jejunum, in vitro.

Authors:  M Fromm; J D Schulzke; U Hegel
Journal:  Pflugers Arch       Date:  1985-12       Impact factor: 3.657

9.  Chloride activity in cells of isolated perfused cortical thick ascending limbs of rabbit kidney.

Authors:  R Greger; H Oberleithner; E Schlatter; A C Cassola; C Weidtke
Journal:  Pflugers Arch       Date:  1983-09       Impact factor: 3.657

  9 in total