Literature DB >> 7180396

Standardized photoelectric technique as routine method for selection of amputation level.

M Støckel, J Ovesen, J Brøchner-Mortensen, H Emnéus.   

Abstract

During a period of 11 months 45 amputations, 31 below-knee and 14 above-knee, were performed in 42 patients with gangrene of the lower extremity. A newly introduced standardized photoelectric technique for measurement of local skin perfusion pressure (SPP) was used preoperatively and the result used in selection of the proper amputation level. An overall healing rate of 89 per cent was found. 69 per cent of the amputations were performed below-knee. The healing rates for individual SPP-levels were identical to those obtained with the cumbersome isotope washout technique. The standardized photoelectric technique is simple, rapid and causes the patient only negligible discomfort, allowing repeated measurements on different levels of the leg.

Entities:  

Mesh:

Year:  1982        PMID: 7180396     DOI: 10.3109/17453678208992841

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  1 in total

1.  Antibiotic prophylaxis in lower-extremity amputations due to ischemia. A prospective, randomized trial of cephalothin versus methicillin.

Authors:  S Thomsen; B W Jakobsen; J O Wethelund; J Dalsgaard; H N Gregersen; U Lucht
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067