| Literature DB >> 7176557 |
Abstract
A method is presented for the analysis of ethylene glycol in whole blood by GC/FID using 1,2-butanediol as the internal standard (IS). The diols are derivatized during extraction from whole blood using n-butylboronic acid and then extracted as pseudo weak acids prior to analysis. As little as 10 mg/L of ethylene glycol in blood can be detected by this method.Entities:
Mesh:
Substances:
Year: 1982 PMID: 7176557 DOI: 10.1093/jat/6.5.253
Source DB: PubMed Journal: J Anal Toxicol ISSN: 0146-4760 Impact factor: 3.367