Literature DB >> 717034

Movements in the sacroiliac joints demonstrated with roentgen stereophotogrammetry.

N Egund, T H Olsson, H Schmid, G Selvik.   

Abstract

Using a roentgen stereophotogrammetric method, the three-dimensional movements in the sacroiliac joints were quantified in 4 patients. To provoke motion of the sacrum, changes between body positions and a test with manual pressure were used. In tests with symmetric forces on the sacrum, it in most cases rotated mainly about a transverse axis and at most approximately 2 degrees. The axis of rotation passed through the iliac bones mainly in the lower part of the iliac tuberosity. The rotations between the iliac bones and the sacrum about any of the three main axes were determined with a precision in the mean of 0.2 degrees. The distance between the two superior posterior iliac spines varied at most 0.4 mm between seven different body positions.

Entities:  

Mesh:

Year:  1978        PMID: 717034     DOI: 10.1177/028418517801900513

Source DB:  PubMed          Journal:  Acta Radiol Diagn (Stockh)        ISSN: 0567-8056


  18 in total

1.  Biomechanical behaviour in vitro of the spine and lumbosacral junction.

Authors:  X Barthes; B Walter; R Zeller; J F Dubousset
Journal:  Surg Radiol Anat       Date:  1999       Impact factor: 1.246

2.  Sacroiliac Joint Fusion Minimally Affects Adjacent Lumbar Segment Motion: A Finite Element Study.

Authors:  Derek P Lindsey; Ali Kiapour; Scott A Yerby; Vijay K Goel
Journal:  Int J Spine Surg       Date:  2015-11-13

3.  Three-dimensional movements of the sacroiliac joint: a systematic review of the literature and assessment of clinical utility.

Authors:  Adam Goode; Eric J Hegedus; Philip Sizer; Jean-Michel Brismee; Alison Linberg; Chad E Cook
Journal:  J Man Manip Ther       Date:  2008

4.  Physiological in vitro sacroiliac joint motion: a study on three-dimensional posterior pelvic ring kinematics.

Authors:  Niels Hammer; Mario Scholze; Thomas Kibsgård; Stefan Klima; Stefan Schleifenbaum; Thomas Seidel; Michael Werner; Ronny Grunert
Journal:  J Anat       Date:  2018-12-09       Impact factor: 2.610

5.  Biomechanical modelling of the human sacroiliac joint.

Authors:  N Zheng; L G Watson; K Yong-Hing
Journal:  Med Biol Eng Comput       Date:  1997-03       Impact factor: 2.602

6.  Changes in pelvic anatomy after long corrective fusion using iliac screws for adult spinal deformity.

Authors:  Hiroki Oba; Shigeto Ebata; Jun Takahashi; Shota Ikegami; Kensuke Koyama; Hiroyuki Kato; Hirotaka Haro; Tetsuro Ohba
Journal:  Eur Spine J       Date:  2019-06-21       Impact factor: 3.134

7.  A computed tomographic anatomical study of the upper sacrum. Application for a user guide of pelvic fixation with iliosacral screws in adult spinal deformity.

Authors:  Arnaud Dubory; Houssam Bouloussa; Guillaume Riouallon; Stéphane Wolff
Journal:  Int Orthop       Date:  2017-08-08       Impact factor: 3.075

Review 8.  The sacroiliac joint: an overview of its anatomy, function and potential clinical implications.

Authors:  A Vleeming; M D Schuenke; A T Masi; J E Carreiro; L Danneels; F H Willard
Journal:  J Anat       Date:  2012-09-19       Impact factor: 2.610

9.  Authors' response to the letter to the editors by Professor M. T. Cibulka: a critical interpretation of sacroiliac joint movement studies.

Authors:  A Vleeming; M D Schuenke; B Sturesson; F H Willard
Journal:  J Anat       Date:  2013-03       Impact factor: 2.610

10.  Some aspects of knee joint kinematics in rheumatoid arthritis as studied with roentgen stereophotogrammetry.

Authors:  K B Eberhardt; G Selvik
Journal:  Clin Rheumatol       Date:  1986-06       Impact factor: 2.980

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.