Literature DB >> 7161291

Failure properties of passive human aortic tissue. I--uniaxial tension tests.

D Mohan, J W Melvin.   

Abstract

Samples of descending mid-thoracic aortas were obtained from human autopsies and experiments were performed to determine the effect of strain rate and direction of loading on the failure properties of the tissue in uniaxial tension. The tests were performed at quasi-static strain rates in the range 0.01 s-1-0.07 s-1 and dynamic tests in the range 80 s-1-100 s-1. Ultimate stress and extension ratio values have been calculated for specimens tested in the longitudinal and transverse directions of the aorta.

Entities:  

Mesh:

Year:  1982        PMID: 7161291     DOI: 10.1016/0021-9290(82)90055-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  22 in total

1.  Investigation of inhomogeneous and anisotropic material behavior of porcine thoracic aorta using nano-indentation tests.

Authors:  Golriz Kermani; Ali Hemmasizadeh; Soroush Assari; Michael Autieri; Kurosh Darvish
Journal:  J Mech Behav Biomed Mater       Date:  2016-12-24

2.  Quasi-linear viscoelastic modeling of arterial wall for surgical simulation.

Authors:  Tao Yang; Chee Kong Chui; Rui Qi Yu; Jing Qin; Stephen K Y Chang
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-04-13       Impact factor: 2.924

Review 3.  The time has come to extend the expiration limit of cryopreserved allograft heart valves.

Authors:  Jan Burkert; Petra Kochová; Zbyněk Tonar; Robert Cimrman; Tereza Blassová; Ramadan Jashari; Radovan Fiala; Jaroslav Špatenka
Journal:  Cell Tissue Bank       Date:  2020-06-24       Impact factor: 1.522

Review 4.  Cause and control of automotive trauma.

Authors:  D C Viano
Journal:  Bull N Y Acad Med       Date:  1988-06

5.  Failure properties and microstructure of healthy and aneurysmatic human thoracic aortas subjected to uniaxial extension with a focus on the media.

Authors:  Selda Sherifova; Gerhard Sommer; Christian Viertler; Peter Regitnig; Thomas Caranasos; Margaret Anne Smith; Boyce E Griffith; Ray W Ogden; Gerhard A Holzapfel
Journal:  Acta Biomater       Date:  2019-08-26       Impact factor: 8.947

6.  Biomechanical analysis of the splenic avulsion mechanism.

Authors:  Omar Chebil; Michel Behr; Florent Auriault; Pierre-Jean Arnoux
Journal:  Med Biol Eng Comput       Date:  2014-06-19       Impact factor: 2.602

7.  A Uniaxial Testing Approach for Consistent Failure in Vascular Tissues.

Authors: 
Journal:  J Biomech Eng       Date:  2018-06-01       Impact factor: 2.097

8.  Microcrimped collagen fiber-elastin composites.

Authors:  Jeffrey M Caves; Vivek A Kumar; Wenjun Xu; Nisarga Naik; Mark G Allen; Elliot L Chaikof
Journal:  Adv Mater       Date:  2010-05-11       Impact factor: 30.849

9.  Computer-aided vascular experimentation: a new electromechanical test system.

Authors:  J D Humphrey; T Kang; P Sakarda; M Anjanappa
Journal:  Ann Biomed Eng       Date:  1993       Impact factor: 3.934

10.  Hydrazone self-crosslinking of multiphase elastin-like block copolymer networks.

Authors:  Urlam Murali Krishna; Adam W Martinez; Jeffrey M Caves; Elliot L Chaikof
Journal:  Acta Biomater       Date:  2011-12-02       Impact factor: 8.947

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.