Literature DB >> 7154647

Determination of perfusion field during local hyperthermia with the aid of finite element thermal models.

K M Sekins, A F Emery, J F Lehmann, J A MacDougall.   

Abstract

Two-dimensional transient thermal models of human thighs undergoing microwave diathermy are developed with the aid of experimental data to shed light on the blood flow response occurring during local hyperthermia in muscle. The experimental data were taken from tests on six human subjects treated with a 915-Mz, direct-contact microwave diathermy device which incorporated a system for simultaneously cooling the skin surface with a cold air stream. The numerically calculated perfusion fields were determined by systematically varying a model's blood flow response to the temperature stimulus until good agreement between the experimental and model temperature fields were achieved. The model blood flow values were then checked against those measured in the human experiments via xenon 133 washout and good agreement here was also found. The future use of models of this type in clinical diagnosis and hyperthermic treatment is proposed.

Entities:  

Mesh:

Year:  1982        PMID: 7154647     DOI: 10.1115/1.3138359

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  5 in total

1.  Calcific tendinitis of the rotator cuff: a review.

Authors:  Sushil G Kachewar; Devidas S Kulkarni
Journal:  J Clin Diagn Res       Date:  2013-07-01

2.  Effects of Microwave Hyperthermia at Two Different Frequencies (434 and 2450 MHz) on Human Muscle Temperature.

Authors:  Noriko Ichinoseki-Sekine; Hisashi Naito; Norio Saga; Yuji Ogura; Minoru Shiraishi; Arrigo Giombini; Valentina Giovannini; Shizuo Katamoto
Journal:  J Sports Sci Med       Date:  2008-03-01       Impact factor: 2.988

3.  Changes in muscle temperature induced by 434 MHz microwave hyperthermia.

Authors:  Noriko Ichinoseki-Sekine; Hisashi Naito; Norio Saga; Yuji Ogura; Minoru Shiraishi; Arrigo Giombini; Valentina Giovannini; Shizuo Katamoto
Journal:  Br J Sports Med       Date:  2007-01-29       Impact factor: 13.800

4.  MR-guided transcranial brain HIFU in small animal models.

Authors:  B Larrat; M Pernot; J-F Aubry; E Dervishi; R Sinkus; D Seilhean; Y Marie; A-L Boch; M Fink; M Tanter
Journal:  Phys Med Biol       Date:  2009-12-17       Impact factor: 3.609

5.  Low dose of continuous-wave microwave irradiation did not cause temperature increase in muscles tissue adjacent to titanium alloy implants--an animal study.

Authors:  Dongmei Ye; Yiming Xu; Tengfei Fu; Han Zhang; Xianxuan Feng; Gang Wang; Lan Jiang; Yuehong Bai
Journal:  BMC Musculoskelet Disord       Date:  2013-12-23       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.