Literature DB >> 7140481

Is the central dogma of flow cytometry true: that fluorescence intensity is proportional to cellular dye content?

M Kerker, M A Van Dilla, A Brunsting, J P Kratohvil, P Hsu, D S Wang, J W Gray, R G Langlois.   

Abstract

Measurements and theoretical calculations of fluorescent emission from four samples of polystyrene microspheres (diameter 0.92, 1.63, 1.90 and 4.18 microns) containing the same fluorescent dye show a general dependence upon particle size, emission angle, and polarization conditions. However, for the excitation and detection conditions used in flow cytometry, the relative fluorescent intensities measured for the four particle sizes are proportional to the dye content to +10% accuracy, independent of particle size. Accordingly, the central dogma of flow cytometry 'that fluorescence is proportional to cellular dye content' is valid to this accuracy for these solid, highly refractive polymer particles. Most mammalian cells are much less refractive, therefore, should conform more closely to the central dogma.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7140481     DOI: 10.1002/cyto.990030202

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  7 in total

1.  Flow cytometric analysis of the cell cycle: mathematical modeling and biological interpretation.

Authors:  J Pierrez; X Ronot
Journal:  Acta Biotheor       Date:  1992-09       Impact factor: 1.774

2.  Method for flow cytometric detection of Listeria monocytogenes in milk.

Authors:  C W Donnelly; G J Baigent
Journal:  Appl Environ Microbiol       Date:  1986-10       Impact factor: 4.792

3.  Catch strip assay for the relative assessment of two-dimensional protein association kinetics.

Authors:  Brian J Schmidt; Peter Huang; Kenneth S Breuer; Michael B Lawrence
Journal:  Anal Chem       Date:  2008-01-25       Impact factor: 6.986

4.  Intensity correlation-based calibration of FRET.

Authors:  László Bene; Tamás Ungvári; Roland Fedor; László Sasi Szabó; László Damjanovich
Journal:  Biophys J       Date:  2013-11-05       Impact factor: 4.033

5.  Application of flow cytometry to detection and characterization of Legionella spp.

Authors:  R L Tyndall; R E Hand; R C Mann; C Evans; R Jernigan
Journal:  Appl Environ Microbiol       Date:  1985-04       Impact factor: 4.792

6.  Flow cytometric analysis of the DNA synthetic cycle of Candida species.

Authors:  J A Dvorak; W L Whelan; J P McDaniel; C C Gibson; K J Kwon-Chung
Journal:  Infect Immun       Date:  1987-06       Impact factor: 3.441

7.  Digital imaging fluorescence microscopy: spatial heterogeneity of photobleaching rate constants in individual cells.

Authors:  D M Benson; J Bryan; A L Plant; A M Gotto; L C Smith
Journal:  J Cell Biol       Date:  1985-04       Impact factor: 10.539

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.