Abstract

Anterior, posterior, and combined thoracolumbar spinal injuries were simulated in human cadaver specimens and then stressed in flexion, before and after stabilization, with Weiss Springs, Roy-Camille plates, vertebral body plates, and Harrington compression and distraction rods. The reduction, stability, and strength were determined for each implant-injury combination. For posterior ligamentous injuries, the Harrington compression system on the laminae gave reduction in extension, stability to that of the intact spine, and failure at 87.6 Nm bending load with 14.1 J energy absorption. For anterior vertebral body fracture, Harrington distraction rods from three vertebrae above to three below the injury gave a reduction in extension with stability similar to that of the intact spine. Failure occurred at 81.6 Nm load, one-third greater than with rods two levels above to two below, and 14.0 J energy absorption, twice that for the short rod. The more unstable combined anterior and posterior injury was satisfactorily reduced only by the long distraction system, which failed at 44.1 Nm load, twice that for the short rod, and 5.7 J energy absorption. By accurately determining what structures have been injured, and appropriate fixation device can be selected and the strength of the stabilized spine estimated. A thorough understanding of the biomechanics of the spine is essential for successful clinical utilization of these experimental data.

Entities:  

Mesh:

Year:  1982        PMID: 7140083

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

1.  The fixateur interne for stabilising fractures of the thoracolumbar and lumbar spine.

Authors:  E Sim; P M Stergar
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

2.  [Osteosynthesis of severe injuries of the thoracic and lumbar spine with internal fixation].

Authors:  W Dick
Journal:  Langenbecks Arch Chir       Date:  1984

3.  Analysis of 75 operated thoracolumbar fractures and fracture dislocations with and without neurological deficit.

Authors:  M Aebi; J Mohler; G Zäch; E Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1986

4.  [Fractures of the lumbar spine and the lower thoracic spine--surgical technic and results].

Authors:  A Dörner; U Mommsen; S Müller; K H Jungbluth
Journal:  Unfallchirurgie       Date:  1985-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.