Literature DB >> 7139947

Measurement of glycosylated haemoglobins using an affinity chromatography method.

B J Gould, P M Hall, J G Cook.   

Abstract

After removal of the labile material, we have measured the stable glycosylated fraction of haemoglobin with a new, commercially available, phenylboronic acid affinity gel, Glycogel B. The mean value was established for 61 non-diabetics as 7.31 (SD +/- 0.92)% and for 108 diabetics as 12.70 (SD +/- 2.88)%. The method is highly reproducible with a coefficient of variation below 2.0%. The effect of changing the temperature from 7 degrees C to 37 degrees C, and pH from 8.1 to 8.9 was investigated. For accurate results the temperature should be maintained between 20 degrees C +/- 1 degree C, and the pH between 8.6 +/- 0.1. A poor, but significant correlation (r = 0.43) between glycosylated haemoglobin and simultaneous blood glucose was shown. There was a good correlation with the agar gel electrophoretic method (r = 0.95). The slope of the regression line was 1.20 which indicates that this affinity method measures more than just HbA1. The affinity method appears to offer selectivity for diabetics than the electrophoretic method.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7139947     DOI: 10.1016/0009-8981(82)90043-2

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  6 in total

Review 1.  Pharmaceutical and biomedical applications of affinity chromatography: recent trends and developments.

Authors:  David S Hage; Jeanethe A Anguizola; Cong Bi; Rong Li; Ryan Matsuda; Efthimia Papastavros; Erika Pfaunmiller; John Vargas; Xiwei Zheng
Journal:  J Pharm Biomed Anal       Date:  2012-01-14       Impact factor: 3.935

2.  J type diabetes revisited.

Authors:  E Y Morrison; D Ragoobirsingh
Journal:  J Natl Med Assoc       Date:  1992-07       Impact factor: 1.798

3.  Measurement of glycosylated haemoglobins and glycosylated plasma proteins in maternal and cord blood using an affinity chromatography method.

Authors:  P M Hall; G M Cawdell; J G Cook; B J Gould
Journal:  Diabetologia       Date:  1983-12       Impact factor: 10.122

Review 4.  Glycosylated haemoglobin: measurement and clinical use.

Authors:  I Peacock
Journal:  J Clin Pathol       Date:  1984-08       Impact factor: 3.411

5.  Unexplained variability of glycated haemoglobin in non-diabetic subjects not related to glycaemia.

Authors:  J S Yudkin; R D Forrest; C A Jackson; A J Ryle; S Davie; B J Gould
Journal:  Diabetologia       Date:  1990-04       Impact factor: 10.122

6.  Deuterium-depleted water stimulates GLUT4 translocation in the presence of insulin, which leads to decreased blood glucose concentration.

Authors:  Miklós Molnár; Katalin Horváth; Tamás Dankó; Ildikó Somlyai; Beáta Zs Kovács; Gábor Somlyai
Journal:  Mol Cell Biochem       Date:  2021-09-12       Impact factor: 3.396

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.