Literature DB >> 7137116

Lack of clinical relevance in routine final subcultures of radiometrically negative BACTEC blood culture vials.

J J Plorde, L G Carlson, M E Dau.   

Abstract

During a 38-month period, 10,106 blood specimens were received in the laboratory for culture. These were inoculated into 26,424 vials and processed using the BACTEC radiometric detection system. Of these vials, 1,914 were eventually found to be microbiologically positive. Isolates from 836 vials were judged to be contaminants. In the remaining 1,078 vials, growth was first detected visually or radiometrically in 1,062 and by final subculture in 16. Growth from these sixteen bottles represented 12 clinically significant bacteremic episodes in as many patients. In nine of these episodes, other culture vials from the same patient were positive radiometrically. Therefore, 358 of 361 (99.2%) bacteremic episodes were detected without the benefit of routine final subcultures. The three patients whose bacteremia was missed were diagnosed clinically and placed on appropriate therapy prior to the detection of the bacteremias by final subculture.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7137116     DOI: 10.1093/ajcp/78.5.753

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  5 in total

Review 1.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

2.  Time to detection of positive BacT/Alert blood cultures and lack of need for routine subculture of 5- to 7-day negative cultures.

Authors:  D J Hardy; B B Hulbert; P C Migneault
Journal:  J Clin Microbiol       Date:  1992-10       Impact factor: 5.948

3.  BacT/Alert: an automated colorimetric microbial detection system.

Authors:  T C Thorpe; M L Wilson; J E Turner; J L DiGuiseppi; M Willert; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

4.  Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles.

Authors:  M P Weinstein; S Mirrett; M L Wilson; L J Harrell; C W Stratton; L B Reller
Journal:  J Clin Microbiol       Date:  1991-05       Impact factor: 5.948

5.  Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

Authors:  M P Weinstein; S Mirrett; L G Reimer; L B Reller
Journal:  J Clin Microbiol       Date:  1989-03       Impact factor: 5.948

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.