Literature DB >> 713416

[Simultaneous comparative renal clearances and renal iodo (I125)-hippurate in man (author's transl)].

J Gurtner, C Vorburger, F Reubi.   

Abstract

In 111 Patients with a wide range of renal function (normal to advanced renal failure) the renal clearances of Na-paraaminohippurate (CPAH) and of Na-orthojodohippurate--J125(COJ(J125(H) have been simultaneously determined under standardized clearance conditions. We found a significant correlation between the 2 parameters, defined by the equation CPAH = 1.11.COJ(J125)H. The scatter of the single observations however is considerable and hence the +/- 2Sy range is very large. The difference between the 2 clearances is not die to a competition at the same tubular carrier, since adding inactive carrier of OJH does not improve the ratio of the 2 clearances: CPAH = 1.13.COJ(J125)H. Rather the renal extraction of OJ(J125)H(EOJ(J125)H is considerably lower (74% than EPAH (90%). Our datas suggest that OJ(J125)H is not a suitable indicator to replace PAH for measurements of real renal plasma flow.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 713416     DOI: 10.1007/bf01479837

Source DB:  PubMed          Journal:  Klin Wochenschr        ISSN: 0023-2173


  14 in total

1.  Evaluation of radioiodinated hipuran for the estimation of renal plasma flow.

Authors:  M K BURBANK; W N TAUXE; F T MAHER; J C HUNT
Journal:  Proc Staff Meet Mayo Clin       Date:  1961-07-19

2.  Preparation and use of I 131 labeled sodium iodohippurate in kidney function tests.

Authors:  M TUBIS; E POSNICK; R A NORDYKE
Journal:  Proc Soc Exp Biol Med       Date:  1960-03

3.  Catheter replacement of the needle in percutaneous arteriography; a new technique.

Authors:  S I SELDINGER
Journal:  Acta radiol       Date:  1953-05       Impact factor: 1.990

4.  THE MEASUREMENT OF THE TUBULAR EXCRETORY MASS, EFFECTIVE BLOOD FLOW AND FILTRATION RATE IN THE NORMAL HUMAN KIDNEY.

Authors:  H W Smith; W Goldring; H Chasis
Journal:  J Clin Invest       Date:  1938-05       Impact factor: 14.808

5.  THE RENAL CLEARANCES OF SUBSTITUTED HIPPURIC ACID DERIVATIVES AND OTHER AROMATIC ACIDS IN DOG AND MAN.

Authors:  H W Smith; N Finkelstein; L Aliminosa; B Crawford; M Graber
Journal:  J Clin Invest       Date:  1945-05       Impact factor: 14.808

6.  Measurement of effective renal plasma-flow by the clearance of 125-I-hippuran.

Authors:  M D Ram; K Evans; G D Chisholm
Journal:  Lancet       Date:  1967-09-23       Impact factor: 79.321

7.  Renal clearance in man of pharmaceuticals containing radioactive iodine.

Authors:  F T Maher; W N Tauxe
Journal:  JAMA       Date:  1969-01-06       Impact factor: 56.272

8.  [Problems in the determination of renal plasma flow using ortho-I-131-hippuric acid].

Authors:  K G Bonatz; H Hardt; W E Adam; S Bettge
Journal:  Klin Wochenschr       Date:  1967-08-15

9.  [Comparative studies on the renal clearance of Na-Cr2Cr51 ethylenediaminetetraacetate, inulin and sodium thiosulfate in humans].

Authors:  C Vorburger; H Riedwyl; F Reubi
Journal:  Klin Wochenschr       Date:  1969-04-15

10.  SIMULTANEOUS MEASUREMENT OF GLOMERULAR FILTRATION RATE AND EFFECTIVE RENAL PLASMA FLOW WITH 57CO-CYANOCOBALAMIN AND 125-I-HIPPURAN.

Authors:  R E CUTLER; H GLATTE
Journal:  J Lab Clin Med       Date:  1965-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.