Mechanical and physiological calibration of four cycle ergometers.

J H Wilmore, S H Constable, P R Stanforth, M J Buono, Y W Tsao, F B Roby, B J Lowdon, R A Ratliff.   

Abstract

Mechanical and physiological calibrations were performed on four research-grade cycle ergometers. Ten subjects rode each ergometer twice in a randomized testing order. The subjects pedaled at 60 rpm for 5 min at each of three power outputs, i.e., 49, 98, and 147 W. Heart rate, metabolic, and perceptual data were obtained each minute. Prior to and immediately following these test rides, mechanical calibrations were obtained in duplicate. From the mechanical calibrations, Ergometer A was approximately 10% below actual values at each power output. Ergometer B demonstrated a variable error, with the largest percentage and absolute errors occurring at the lower power outputs. Ergometers C and D generally demonstrated less than a +/- 3% error. Following the physiological calibration, Ergometer B exhibited a substantial drift in calibration, while Ergometers A, C, and D maintained their original calibration. The physiological data supported the mechanical calibration, and Ergometer B demonstrated a substantial drift between the first and second trials and produced substantially different results compared with the other three ergometers. Ergometers A, C, and D demonstrated acceptable consistency in results both within trials and among ergometers. These results demonstrate the importance of proper calibration and of understanding the calibration characteristics of ergometers selected for research purposes.

Mesh:

Year:  1982        PMID: 7132652

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  4 in total

Review 1.  Tests of cycling performance.

Authors:  C D Paton; W G Hopkins
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

Review 2.  Reliability of power in physical performance tests.

Authors:  W G Hopkins; E J Schabort; J A Hawley
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

Review 3.  Tests of maximum oxygen intake. A critical review.

Authors:  R J Shephard
Journal:  Sports Med       Date:  1984 Mar-Apr       Impact factor: 11.136

Review 4.  Caveats and Recommendations to Assess the Validity and Reliability of Cycling Power Meters: A Systematic Scoping Review.

Authors:  Anthony Bouillod; Georges Soto-Romero; Frederic Grappe; William Bertucci; Emmanuel Brunet; Johan Cassirame
Journal:  Sensors (Basel)       Date:  2022-01-05       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.