Literature DB >> 7127460

Limitations of ergonovine testing in patients with variant angina.

R K Mautner, B Iteld, T D Giles.   

Abstract

Fourteen patients with variant angina underwent ergonovine testing during diagnostic coronary angiography. The clinical electrocardiographic or angiographic manifestations of coronary artery spasm could not be reproduced in six of these patients. Five patients had chest pain and transient ST-segment elevation within 4 days of the ergonovine study, including three who developed coronary spasm in the catheterization laboratory. It appears that the sensitivity of ergonovine testing in the diagnosis of coronary spasm is lower than previously emphasized.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7127460     DOI: 10.1002/ccd.1810080404

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  1 in total

1.  An unusual cause of blackout with transient loss of consciousness: Prinzmetal angina.

Authors:  Mohammed Majid Akhtar; Rashid Akhtar; Abid Akhtar; Javed Akhtar
Journal:  BMJ Case Rep       Date:  2012-06-14