Correlation of regional breath sound with regional ventilation in emphysema.

Y Ploysongsang, J A Paré, P T Macklem.   

Abstract

We measured regional breath sound intensities (Ib) by a microphone amplifier system in 8 subjects with emphysema. We also measured regional white noise transmissions (Tn) from the same areas in all subjects. The recorded areas were 5, 10, 15, and 20 cm from the apex of the lung just lateral to the right anterior midclavicular line. Xenon ventilation indexes (xenon tidal raw counts, an index of total regional ventilation; xenon equilibration raw counts, an index of ventilating lung volume; xenon ventilation per unit volume (Vr), an index of ventilation per unit volume) were also recorded from the same areas. The Ib, Tn, Ib/Tn (an index of sound generation), and xenon ventilation indexes were all expressed as a fraction of the mean value of all four recorded areas. The Ib and Ib/Tn correlated best with the xenon tidal raw counts, correlated well with the xenon equilibration raw counts, and correlated poorly with Vr. We conclude that Ib and Ib/Tn can be used to quantify regional ventilation in subjects with emphysema.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7125339     DOI: 10.1164/arrd.1982.126.3.526

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  5 in total

1.  Lung sounds.

Authors:  J Earis
Journal:  Thorax       Date:  1992-09       Impact factor: 9.139

2.  Significant differences in flow standardised breath sound spectra in patients with chronic obstructive pulmonary disease, stable asthma, and healthy lungs.

Authors:  L P Malmberg; L Pesu; A R Sovijärvi
Journal:  Thorax       Date:  1995-12       Impact factor: 9.139

3.  Breath sound changes associated with malpositioned endotracheal tubes.

Authors:  H A Mansy; C J O'Connor; R A Balk; R H Sandler
Journal:  Med Biol Eng Comput       Date:  2005-03       Impact factor: 2.602

4.  Lung sound intensity in patients with emphysema and in normal subjects at standardised airflows.

Authors:  H J Schreur; P J Sterk; J Vanderschoot; H C van Klink; E van Vollenhoven; J H Dijkman
Journal:  Thorax       Date:  1992-09       Impact factor: 9.139

5.  The correlation between lung sound distribution and pulmonary function in COPD patients.

Authors:  Masamichi Mineshita; Hirotaka Kida; Hiroshi Handa; Hiroki Nishine; Naoki Furuya; Seiichi Nobuyama; Takeo Inoue; Shin Matsuoka; Teruomi Miyazawa
Journal:  PLoS One       Date:  2014-09-22       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.