Literature DB >> 7115274

Measurement of radioactive tracer microsphere blood flow with NaI (T1)-and Ge-well type detectors.

B Winkler, G Stämmler, W Schaper.   

Abstract

An intrinsic Ge-well type detector was applied for the detection of gamma rays from labeled tracer microspheres. The high energy resolution and the large peak-to-Compton ratio of this spectrometer ensures the application of all available differently labeled tracer microspheres in one experiment. The superior energy resolution of the Ge-detector was documented with the separated photopeak regions of 103-Ru and 85-Sr-labeled tracer microspheres, which result in a single photopeak when an NaI(T1) detector is used. The Ge-well type detector was compared with an NaI(T1) spectrometer by counting samples of cardiac muscle in either spectrometer systems. Regression analysis between both spectrometer systems demonstrate identical flow values in these samples for 5 differently labeled tracer microspheres which were administered in 5 dogs. The high sensitivity of the Ge-well-type detector together with a suitable technique for sampling of myocardial tissue accomplishes a high spatial resolution of myocardial perfusion for all available differently labeled tracer microspheres.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7115274     DOI: 10.1007/bf01908044

Source DB:  PubMed          Journal:  Basic Res Cardiol        ISSN: 0300-8428            Impact factor:   17.165


  3 in total

1.  Blood flow measurements with radionuclide-labeled particles.

Authors:  M A Heymann; B D Payne; J I Hoffman; A M Rudolph
Journal:  Prog Cardiovasc Dis       Date:  1977 Jul-Aug       Impact factor: 8.194

2.  Myocardial steal produced by coronary vasocilation in chronic coronary artery occlusion.

Authors:  W Schaper; P Lewi; W Flameng; L Gijpen
Journal:  Basic Res Cardiol       Date:  1973 Jan-Feb       Impact factor: 17.165

3.  The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow.

Authors:  A M Rudolph; M A Heymann
Journal:  Circ Res       Date:  1967-08       Impact factor: 17.367

  3 in total
  3 in total

1.  Microvascular and collateral adaptation in swine hearts following progressive coronary artery stenosis.

Authors:  G Görge; T Schmidt; B R Ito; G A Pantely; W Schaper
Journal:  Basic Res Cardiol       Date:  1989 Sep-Oct       Impact factor: 17.165

Review 2.  Glossary: methods for the measurement of coronary blood flow and myocardial perfusion.

Authors:  S G Sakka; D R Wallbridge; G Heusch
Journal:  Basic Res Cardiol       Date:  1996 Mar-Apr       Impact factor: 17.165

3.  Autonomic modulation of insulin levels in foetal sheep.

Authors:  U Lang; A Jensen; W Künzel
Journal:  Clin Auton Res       Date:  1993-10       Impact factor: 4.435

  3 in total