Literature DB >> 7104276

Use of portable vitrectomy instrumentation (VISC X) in the rural Guatemalan highlands.

J D Kingham, R H Poirier, M Annel, D Erickson.   

Abstract

In a rural mountain setting 20 patients with blinding ocular opacities were treated surgically with modern vitrectomy techniques. There were no intraoperative or postoperative complications unique to the isolated environment. Because of its compact portability, the VISC X proved to be an ideal vitrectomy instrument. In addition to plastic lid procedures, cataract extraction, and strabismus surgery, repair of retinal detachment and vitrectomy in selected cases has been added to the armamentarium of surgeons who are seriously involved in exporting ophthalmology to remote places.

Entities:  

Mesh:

Year:  1982        PMID: 7104276      PMCID: PMC1039858          DOI: 10.1136/bjo.66.9.569

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  8 in total

1.  Pars plana vitrectomy for removal of intravitreous Cysticercus.

Authors:  W L Hutton; A Vaiser; W B Snyder
Journal:  Am J Ophthalmol       Date:  1976-05       Impact factor: 5.258

2.  Retinal tears 180 degrees and greater. Management with vitrectomy and intravitreal gas.

Authors:  R Machemer; A W Allen
Journal:  Arch Ophthalmol       Date:  1976-08

3.  Retinal reattachment surgery in the remote Guatemalan highlands.

Authors:  J D Kingham; R H Poirier; R H Wolters; M Annel
Journal:  Ophthalmic Surg       Date:  1978-10

4.  A new concept for vitreous surgery. 4. Improvements in instrumentation and illumination.

Authors:  J M Parel; R Machemer; W Aumayr
Journal:  Am J Ophthalmol       Date:  1974-01       Impact factor: 5.258

5.  Incidence of retinal detachment following cataract extraction.

Authors:  H G Scheie; P H Morse; A Aminlari
Journal:  Arch Ophthalmol       Date:  1973-04

6.  Exporting ophthalmology.

Authors: 
Journal:  Arch Ophthalmol       Date:  1966-07

7.  Pars plana approach for pupillary membranes.

Authors:  G Treister; R Machemer
Journal:  Arch Ophthalmol       Date:  1978-06

8.  Surgery of congenital and juvenile cataracts: a pars plicata approach with the vitrophage.

Authors:  G A Peyman; M Raichand; M F Goldberg
Journal:  Br J Ophthalmol       Date:  1978-11       Impact factor: 4.638

  8 in total
  2 in total

1.  Evaluation of the vitreous microbial contamination rate in office-based three-port microincision vitrectomy surgery using Retrector technology.

Authors:  Flavio A Rezende; Cynthia X Qian; Przemyslaw Sapieha
Journal:  BMC Ophthalmol       Date:  2014-05-01       Impact factor: 2.209

2.  Commentary: Office-based vitrectomy using topical anesthesia in an Indian setting.

Authors:  Ashwin Mohan; Ramesh Venkatesh
Journal:  Indian J Ophthalmol       Date:  2018-08       Impact factor: 1.848

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.