Literature DB >> 7102282

Use of a guide instrument for compartmental knee arthroplasty.

A Lindstrand, T Boegård, N Egund, K G Thorngren.   

Abstract

To improve the positioning of the tibial component in compartmental knee arthroplasty a guide instrument was introduced. With the guide instrument the position in the frontal plane significantly improved from a mean medial slope of 10 degrees to 2 degrees. In the sagittal plane the change from a mean posterior slope of 5 degrees to 3 degrees was insignificant. The mean value for the Hip-Knee-Ankle angle (HKA) (ideal 180 degrees) was 186 degrees after "free-hand" operation and 183 degrees with the modified operative technique. Thus, it is possible with the aid of a guide instrument to improve the precision in compartmental knee arthroplasty.

Mesh:

Year:  1982        PMID: 7102282     DOI: 10.3109/17453678208992270

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  6 in total

Review 1.  Ten-year results of tibial osteotomy for medial gonarthrosis. The influence of overcorrection.

Authors:  S Odenbring; N Egund; B Hagstedt; J Larsson; A Lindstrand; S Toksvig-Larsen
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

2.  The influence of metal backing in unicompartmental tibial component fixation. An in vivo roentgen stereophotogrammetric analysis of micromotion.

Authors:  L Ryd; A Lindstrand; A Stenström; G Selvik
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

3.  Fixation of the tibial component in knee arthroplasty after six weeks.

Authors:  S Toksvig-Larsen; L Ryd; A Lindstrand
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

4.  Micromotion of conventionally cemented all-polyethylene tibial components in total knee replacements. A roentgen stereophotogrammetric analysis of migration and inducible displacement.

Authors:  L Ryd; A Lindstrand; R Rosenquist; G Selvik
Journal:  Arch Orthop Trauma Surg       Date:  1987

5.  Tibial plateau strength patterns in experimental modular knee replacement.

Authors:  I Hvid; J T Møller
Journal:  Arch Orthop Trauma Surg       Date:  1985

6.  Preoperative tibial mechanical axis orientation and articular surface design influence on the coronal joint line orientation relative to the ground during gait after total knee arthroplasties.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Yasuharu Nakashima
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-03-20       Impact factor: 4.342

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.