Literature DB >> 709873

A simple screening method for plasma lipids by thin-layer chromatography with flame ionization detection.

D Vandamme, G Vankerckhoven, R Vercaemst, F Soetewey, V Blaton, H Peeters, M Rosseneu.   

Abstract

Thin-layer chromatography was carried out on glass rods coated with Silica gel (chromarod) and the fractions were detected with a flame ionization detector (FID). This system was applied to the fractionation and screening of plasma lipids. As the relative response of the flame ionization detector depends on the nature of the lipids, correction factors had to be introduced. These correction factors were derived from comparison of the results of the thin-layer chromatography with flame ionization detection with those obtained by conventional chemical analysis of the same sample. The coefficients of variation of the lipid profiles were comparable for both techniques. The absolute lipid concentration for the various fractions obtained by combination of the concentration of the total lipids with the relative lipid profile, correlate very well with the values obtained by conventional chemical analysis of the various lipids.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 709873     DOI: 10.1016/0009-8981(78)90321-2

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  5 in total

1.  Effect of suloctidil on rat liver.

Authors:  D Thines-Sempoux; C Bovy-Kesler; E Debruyne; J Roba
Journal:  Arch Toxicol       Date:  1986-07       Impact factor: 5.153

2.  Comparative studies on composition of cardiac phospholipids in rats fed different vegetable oils.

Authors:  J K Kramer
Journal:  Lipids       Date:  1980-09       Impact factor: 1.880

3.  Complexities in lipid quantitation using thin layer chromatography for separation and flame ionization for detection.

Authors:  R T Crane; S C Goheen; E C Larkin; G A Rao
Journal:  Lipids       Date:  1983-01       Impact factor: 1.880

4.  Quantitating heart lipids: comparison of results obtained using the Iatroscan method with those from phosphorus and gas chromatographic techniques.

Authors:  J K Kramer; E R Farnworth; B K Thompson
Journal:  Lipids       Date:  1985-08       Impact factor: 1.880

5.  Comparison of the thin layer chromatography/flame ionization detection system with other methods for the quantitative analysis of liver lipid contents in alcohol-fed rats and controls.

Authors:  G A Rao; D E Riley; E C Larkin
Journal:  Lipids       Date:  1985-08       Impact factor: 1.880

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.