The relation between arterial viscoelasticity and wave propagation in the canine femoral artery in vivo.

W R Milnor, C D Bertram.   

Abstract

The influence of arterial dimensions and viscoelasticity on pulse wave propagation has been expressed in many theoretical models of blood flow in arteries, but few experimental tests of these theories in vivo have been reported. The measurements required for such tests include not only the arterial viscoelasticity, diameter, and wall thickness, but also the true propagation coefficients and impedances, for comparison with the values "predicted" by solution of the model equations. We made such measurements in 16 experiments on the femoral artery in nine anesthetized dogs. A two-point pressure and flow technique was used to measure wave propagation, and an ultrasonic micrometer was used to measure vessel diameter as a function of time and pressure. Measured attenuation constants ranged from 0.010 at 1.3 Hz to 0.075 at 12.7 Hz, and were more than twice as large as those predicted by two representative linear models. True phase velocity, which increased from 6.71 m/sec at 1.3 Hz to 10.54 m/sec at 12.7 Hz, agreed closely with the values computed by the Cox model but were lower than those given by the Jager model. The resistive, but not the reactive, component of longitudinal impedance was significantly greater than predicted by the models at all frequencies. The experiments do not identify the source of these discrepancies. The use of linear models to calculate pulsatile blood flow from pressure gradients in relatively small vessels, or to calculate attenuation and characteristic impedance from arterial viscoelasticity in vessels of any size, produces significant errors.

Entities:  

Mesh:

Year:  1978        PMID: 709749     DOI: 10.1161/01.res.43.6.870

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  9 in total

1.  Effect of compliance on a time-domain estimate of the characteristic impedance of the pulmonary artery during acute pulmonary hypertension.

Authors:  P R Fourie; A R Coetzee
Journal:  Med Biol Eng Comput       Date:  1993-09       Impact factor: 2.602

2.  Wave propagation with different pressure signals: an experimental study on the latex tube.

Authors:  M Ursino; E Artioli; M Gallerani
Journal:  Med Biol Eng Comput       Date:  1993-07       Impact factor: 2.602

Review 3.  The development of recognition of component significance in closed-loop cardiovascular control.

Authors:  A Noordergraaf; J Melbin
Journal:  Ann Biomed Eng       Date:  1980       Impact factor: 3.934

4.  Influence of the distensibility of large arteries on the longitudinal impedance: application for the development of non-invasive techniques to the diagnosis of arterial diseases.

Authors:  Ridha Ben Salah; Wassila Sahtout
Journal:  Nonlinear Biomed Phys       Date:  2012-04-16

5.  Numerical assessment of time-domain methods for the estimation of local arterial pulse wave speed.

Authors:  Jordi Alastruey
Journal:  J Biomech       Date:  2011-01-05       Impact factor: 2.712

6.  The reasons why fractional flow reserve and instantaneous wave-free ratio are similar using wave separation analysis.

Authors:  Soohong Min; Gwansuk Kang; Dong-Guk Paeng; Joon Hyouk Choi
Journal:  BMC Cardiovasc Disord       Date:  2021-01-25       Impact factor: 2.298

7.  Optimized design of an arterial network model reproduces characteristic central and peripheral haemodynamic waveform features of young adults.

Authors:  Avinash Kondiboyina; Hilary A Harrington; Joseph J Smolich; Michael M H Cheung; Jonathan P Mynard
Journal:  J Physiol       Date:  2022-08-02       Impact factor: 6.228

8.  Ageing, hypertension and aortic valve stenosis - Understanding the series circuit using cardiac magnetic resonance and applanation tonometry.

Authors:  S L Hungerford; A I Adji; N K Bart; L Lin; N Song; A Jabbour; M F O'Rourke; C S Hayward; D W M Muller
Journal:  Int J Cardiol Hypertens       Date:  2021-05-28

9.  Aging is Associated With an Earlier Arrival of Reflected Waves Without a Distal Shift in Reflection Sites.

Authors:  Timothy S Phan; John K-J Li; Patrick Segers; Maheswara Reddy-Koppula; Scott R Akers; Samuel T Kuna; Thorarinn Gislason; Allan I Pack; Julio A Chirinos
Journal:  J Am Heart Assoc       Date:  2016-08-29       Impact factor: 5.501

  9 in total